English
Language : 

G3VM-21PR11 Datasheet, PDF (2/3 Pages) Omron Electronics LLC – Smallest Class in market, USOP High-power, 0.9A Switching in a 20V Load Voltage Model
G3VM-21PR11
MOS FET Relays
■Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum Typical Maximum
Unit
Load voltage (AC peak/DC)
VDD
Operating LED forward current
IF
Continuous load current (AC peak/DC)
IO
Ambient operating temperature
Ta
−
−
16
V
5
7.5
20
mA
−
−
900
mA
−20
−
65
°C
■Engineering Data
LED forward current vs.
Ambient temperature
IF - Ta
60
50
40
30
20
10
0
-40 -20
0 20 40 60 80 100
Ambient temperature Ta (°C)
Continuous load current vs.
On-state voltage
1000
IO - VON
Ta=25°C
IF=5mA
500
t<1s
0
-500
-1000
-0.2
-0.1
0
0.1
0.2
On-state voltage VON (V)
Turn ON, Turn OFF time vs.
LED forward current
tON, tOFF - IF
1000
tOFF
100
10
1
VDD=10V
RL=200Ω
tON
Ta=25°C
10
100
LED forward current IF (mA)
Output terminal capacitance
COFF/COFF(ov) vs. Load voltage
COFF - VOFF
1.2
Ta=25°C
1
0.8
0.6
0.4
0.2
0
0
5
10
15
20
Load voltage VOFF (v)
Continuous load current vs.
Ambient temperature
IO - Ta
1000
800
600
400
200
0
-40 -20
0 20 40 60 80 100
Ambient temperature Ta (°C)
On-state resistance vs.
Ambient temperature
RON - Ta
0.5
Io=900mA
0.4
IF=5mA
t<1s
0.3
0.2
0.1
0
-40 -20
0 20 40 60 80 100
Ambient temperature Ta (°C)
Turn ON, Turn OFF time vs.
Ambient temperature
tON, tOFF - Ta
tON
1000
tOFF
100
10
-40
VDD=10V
RL=200Ω
IF=5mA
-20 0 20 40 60 80 100
Ambient temperature Ta (°C)
LED forward current vs.
LED forward voltage
IF - VF
100
Ta=25°C
10
1
0.1
0.8
1
1.2
1.4
1.6
LED forward voltage VF (V)
Trigger LED forward current vs.
Ambient temperature
IFT - Ta
2
Io=100mA
t<1s
1
0
-40 -20
0 20 40 60 80 100
Ambient temperature Ta (°C)
Current leakage vs.
Load voltage
U
S
ILEAK - VOFF
O
100
P
Ta=25°C
80
G
60
3
V
40
M
20
I
2
0
0
5
10
15
20
1
P
Load voltage VOFF (v)
R
1
1
■Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2