English
Language : 

G3VM-101HR Datasheet, PDF (2/2 Pages) Omron Electronics LLC – MOS FET Relays
G3VM-101HR
G3VM-101HR
■ Absolute Maximum Ratings (Ta = 25°C)
Input
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Output Load voltage (AC peak/DC)
Continuous load
current
Connection A
Connection B
Connection C
ON current reduction Connection A
rate
Connection B
Connection C
Pulse on current
Connection temperature
Dielectric strength between input and
output (See note 1.)
Operating temperature
Storage temperature
Soldering temperature (10 s)
Symbol
IF
∆ IF/°C
VR
Tj
VOFF
IO
∆ IIO/°C
Iop
Tj
VI-O
Ta
Tstg
---
Rating
30
−0.3
5
125
100
1.4
1.4
2.8
−18.7
−18.7
−37.3
4
125
1,500
Unit
mA
mA/°C
V
°C
V
A
mA/°C
A
°C
Vrms
−40 to +85 °C
−55 to +125 °C
260
°C
Measurement Conditions
Ta ≥ 25°C
Connection A: AC peak/DC
Connection B and C: DC
Ta ≥ 50°C
t = 100 ms
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note:
1. The dielectric strength between the in-
put and output was checked by apply-
ing voltage between all pins as a
group on the LED side and all pins as
a group on the light-receiving side.
Connection Diagram
Connection
A
1 6 Load
2
5
or
AC
DC
34
Connection
B
1 6 Load
25
DC
34
Connection
C
1 6 Load
25
DC
34
■ Electrical Characteristics (Ta = 25°C)
Item
Symbol
Input
Output
LED forward voltage
VF
Reverse current
IR
Capacity between terminals
CT
Trigger LED forward current
IFT
Maximum resistance Connection A RON
with output ON
Connection B
Connection C
Current leakage when the relay is
open
ILEAK
Capacity between I/O terminals
CI-O
Insulation resistance
RI-O
Mini-
mum
1.18
---
---
---
---
---
---
---
---
1,000
Turn-ON time
Turn-OFF time
tON
---
tOFF
---
Typical
1.33
Maxi-
mum
1.48
---
10
70
---
0.4
3
0.1
0.2
0.05
0.1
0.025 ---
---
10
0.8
---
---
---
1.0
5.0
0.15
1.0
Unit
V
µA
pF
mA
Ω
Ω
Ω
nA
Measurement
conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 100 mA
IF = 5 mA, IO = 1.4 A, t < 1S
IF = 5 mA, IO = 1.4 A, t < 1S
IF = 5 mA, IO = 2.8 A, t < 1S
VOFF = 100 V
pF
f = 1 MHz, Vs = 0 V
MΩ
VI-O = 500 VDC,
RoH ≤ 60%
ms
IF = 5 mA, RL = 200 Ω,
ms
VDD = 20 V (See note 2.)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Note:
2. Turn-ON and Turn-OFF
Times
IF 1
2
6 RL
VDD
4
VOUT
IF
VOUT
t ON
10%
90%
t OFF
Item
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Operating temperature
Symbol
VDD
IF
IO
Ta
Minimum
---
5
---
−20
■ Engineering Data
Load Current vs. Ambient Temperature
G3VM-101HR
Typical
---
7.5
---
---
Maximum
100
20
1.1
65
Unit
V
mA
A
°C
■ Safety Precautions
Refer to “Common Precautions” for all G3VM models.
3
Connection C
2.5
2
1.5 Connection A, Connection B
1
0.5
0
−20 0
20
40
60
80 100
Ambient temperature (°C)
55