English
Language : 

G3VM-101AR Datasheet, PDF (2/4 Pages) Omron Electronics LLC – MOS FET Relays G3VM-101AR/DR
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol Rating
Unit Measurement conditions
Input LED forward current
IF
30
mA
Repetitive peak LED forward IFP
1
A
current
LED forward current
reduction rate
Δ IF/°C −0.3
mA/°C
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
°C
Output Load voltage (AC peak/DC) VOFF 100
V
Continuous load current
IO
1
A
(AC peak/DC)
ON current reduction rate Δ ION/°C −10
mA/°C
Pulse ON current
IOP
3
A
Connection temperature
Tj
125
°C
Dielectric strength between input and VI-O
2,500
Vrms
output (See note 1.)
Operating temperature
Ta
−40 to +85 °C
Storage temperature
Tstg
−55 to +125 °C
Soldering temperature (10 s)
---
260
°C
100 μs pulses, 100 pps
Ta ≥ 25°C
Note:
Ta ≥ 25°C
t=100 mS, Duty = 1/10
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical
Maxi-
mum
Unit
Measurement
conditions
Input LED forward voltage
VF
Reverse current
IR
Capacity between terminals
CT
Trigger LED forward current
IFT
Output Maximum resistance with output ON RON
Current leakage when the relay is open ILEAK
Capacity between terminals
COFF
Capacity between I/O terminals
CI-O
Insulation resistance between I/O terminals
RI-O
Turn-ON time
tON
Turn-OFF time
tOFF
1.18
---
---
---
---
---
---
---
1,000
---
---
1.33 1.48 V
---
10
μA
70
---
pF
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
Note:
0.5
3
mA IO = 1 A
250
700
mΩ IF = 5 mA,
IO =1 A, t < 1 s
---
1.0
μA
VOFF = 100 V
200 ---
pF
V = 0, f = 1MHz
0.8
---
pF
f = 1 MHz, Vs = 0 V
---
---
MΩ VI-O = 500 VDC,
RoH ≤ 60%
0.8
5.0
ms
IF = 5 mA, RL = 200 Ω,
0.3
1.0
ms
VDD = 20 V (See note 2.)
2. Turn-ON and Turn-OFF
Times
IF 1
2
4 RL
VDD
3
VOUT
IF
VOUT
t ON
10%
90%
t OFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Load voltage (AC peak/DC)
VDD
Operating LED forward current
IF
Continuous load current (AC peak/DC) IO
Operating temperature
Ta
Minimum
---
5
---
− 20
Typical
---
10
---
---
Maximum
Unit
80
V
25
mA
1
A
65
°C
2
MOS FET Relays G3VM-101AR/DR