G3JS403BLDC1224 Datasheet, PDF (2/4 Pages) Omron Electronics LLC – Soft-start Solid State Contactors
Ordering Information
G3J-S
■ List of Models
Number of
elements
3
Insulation method Rated supply
voltage
Phototriac
12 to 24 VDC
Input method
No-voltage input
(open and short-
circuit input)
Applicable motor
2.2 kW (5.5 A)
0.75 kW (2.4 A)
2.2 kW (11.1 A)
0.75 kW (4.8 A)
380 to 400 VAC
200 to 220 VAC
Note: When ordering, specify the rated supply voltage.
■ Accessories (Order Separately)
Model
G3J-S405BL
G3J-S403BL
G3J-S211BL
G3J-S205BL
Mounting Bracket
Model
R99-14 FOR G3J (See note.)
Note: Use this Bracket when mounting Thermal Relay to a G3J-series SSR.
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
Power Supply
Rated supply voltage
Operating voltage range
Current consumption
12 to 24 VDC
10.2 to 26.4 VDC
100 mA max. (at 12 to 24 VDC)
Operation Circuit
Input current
Input method
No-voltage input (short-circuiting and
opening inputs) (See note.)
10 mA max. (at 12 to 24 VDC)
Short-circuiting or opening terminals 1 and COM or 2 (+) and 1
SSR input turned ON: A maximum residual voltage of 2 V between short-circuited terminals
SSR input turned OFF: A maximum leakage current of 0.15 mA
Relay input: For minute signals
Note: Refer to Safety Precautions for the G3J-T, G3J-S, and G3J.
Main Circuit
Item
Rated load voltage
Load voltage range
Rated carry current
Min. load current
Peak-value current resistivity
Overload resistance
Closed current AC3
(effective value) AC4
Breaking current AC3
(effective value) AC4
Applicable load
3-phase inductive
motor (AC3 AC4
AC53-a)
Resistive load
(AC1) (See note.)
G3J-S405BL
G3J-S403BL
G3J-S211BL
G3J-S205BL
200 to 400 VAC (50/60 Hz)
200 to 240 VAC (50/60 Hz)
180 to 440 VAC (50/60 Hz)
180 to 264 VAC (50/60 Hz)
5.5 A (Ta = 40°C)
2.4 A (Ta = 40°C)
11.1 A (Ta = 40°C)
4.8 A (Ta = 40°C)
0.5 A
220 A, 60 Hz, 1 cycle 96 A, 60 Hz, 1 cycle 350 A, 60 Hz, 1 cycle 150 A, 60 Hz, 1 cycle
Refer to Information Common to the G3J, G3J-T, and G3J-S.
55 A
24 A
111 A
48 A
66 A
28.8 A
133.2 A
57.6 A
44 A
19.2 A
88.8 A
38.4 A
55 A
24 A
111 A
48 A
380 to 400 VAC, 2.2 kW, 380 to 400 VAC,
5.5 A
0.75 kW, 2.4 A
200 to 220 VAC, 2.2 kW, 200 to 220 VAC,
11.1 A
0.75 kW, 4.8 A
Motors passing the AC3-class, AC4-class, and AC53-a-class switching frequency test (Ta = 40°C)
under conditions specified by OMRON. Refer to Information Common to the G3J, G3J-T, and G3J-S.
200 to 400 VAC, 5.5 A 200 to 400 VAC, 2.4 A 200 to 240 VAC, 11.1 A 200 to 240 VAC, 4.8 A
Note: No single-phase load can be connected.
2