■ Characteristics
Operate time (see note)
6 ms max.
Release time (see note)
10 ms max.
Output ON-resistance (see note) 2.4 Ω max.
Leakage current
10 μA max. (at 125 VDC)
Insulation resistance
100 MΩ min. (500 VDC)
Dielectric strength
2,500 VAC, 50/60 Hz for 1 min between input and output
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Malfunction: 1,000 m/s2
Ambient temperature
Operating: -30°C to 85°C (with no icing or condensation)
Storage: -30°C to 100°C (with no icing or condensation)
Approved standards
UL File No. E64562
CSA File No. LR35535
Ambient humidity
Operating 45% to 85%
Weight
Approx. 3.1 g