English
Language : 

ES1B Datasheet, PDF (2/8 Pages) Omron Electronics LLC – Infrared Thermosensor
Specifications
■ Ratings/Characteristics
Item
ES1B
Power supply voltage
12/24 VDC
Operating voltage range
90% to 110% of the power supply voltage
Current consumption
20 mA max.
Measuring temperature range
10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C
Accuracy
(See note 1.)
±5°C (See note 2.) ±2% PV or ±2°C, whichever is larger
±10°C (See note 2.) ±4% PV or ±4°C, whichever is larger
±30°C (See note 2.) ±6% PV or ±6°C, whichever is larger
±40°C (See note 2.) ±8% PV or ±8°C, whichever is larger
Reproducibility
±1% PV or ±1°C, whichever is larger
Temperature drift
0.4°C/°C max.
Sensing distance vs. sensing diameter 1:1 typ.
Measurement wavelength
6.5 to 14.0 mm
Receiver element
Thermopile
Response speed
Approximately 300 ms at response rate of 63%
Output impedance
1 to 4 kW
Operating temperature
-25°C to 70°C (with no icing or condensation)
Allowable ambient humidity
35% to 85%
Vibration resistance (destruction)
98 m/s2 for 2 hours each in X, Y, and Z directions at 10 to 55 Hz
Shock resistance (destruction)
300 m/s2 for 3 times each in X, Y, and Z directions
Casing material
ABS resin
Degree of protection
IP65
Weight
Approx. 120 g
Cable
Compensating conductor: 3 m
PVC-covered cable with a shield wire resisting 70°C
Note: 1. Based on characteristics of K-type thermocouple and radiation rate of 0.9.
2. The accuracy is given as the change in temperature from any reference temperature of the sensing object. For example, if the reference
temperature is 50°C, the accuracy at 55°C would be ±2% PV or ±2°C, whichever is larger and the accuracy at 60°C would be ±4% PV
or ±4°C, whichever is larger.
Connections
Green, Output +
White, Output −
+
Thermocouple
(K)
- input terminals
Temperature Controller
Orange, Power +
Shield, Power −
12/24 VDC
GND
DC power supply
2
Infrared Thermosensor ES1B