English
Language : 

E3S5E4S45 Datasheet, PDF (2/5 Pages) Omron Electronics LLC – Ratings and Specifications
Ratings and Specifications
E3S-5E4S-45
Sensing method
Through-beam
Item
Model
E3S-5E4S-45
Sensing distance
Through-beam for paper bags: 200 mm (For standard through-beam use: 10 m)
Standard object
Liquid or solid object, Opaque of 11-mm dia. min.
Directional angle
Emitter/Receiver: 10 to 30° each
Light source (wavelength)
Red LED (890 nm)
Power supply voltage
12 to 24 VDC±10%, ripple (p-p): 10% max.
Current consumption
45 mA max. (Emitter: 25 mA max., Receiver: 20 mA max.)
Control output
Load power supply voltage: 24 VDC max., Load current: 80 mA max. (residual voltage: 1 V max.)
NPN voltage output configuration Light-ON/Dark-ON mode selector
Self-diagnosis output
Load power supply voltage: 24 VDC max., Load current: 50 mA max. (residual voltage: 1 V max.)
Voltage output type
External-diagnosis input
Emission OFF: Short-circuit to 0 V or 1.5 V max. (Outflow current 1 mA max.), Emission ON: Disconnected
(Leakage current 0.1 mA max.)
Protective circuits
Power supply reverse polarity protection, Output short-circuit protection
Response time
Operate or reset: 10 ms max.
Sensitivity adjustment
One-turn adjuster
Ambient illumination
(Receiver side)
Incandescent lamp: 3,000 lx max., Sunlight 10,000 lx max.
Ambient temperature range Operating: −10 to 55°C (with no icing and condensation), Storage: 0 to 65°C (with no icing and condensation)
Ambient humidity range
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance
20 MΩ min. at 500 VDC
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection
IEC 60529 IP67
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 300 g
Case
Zinc die-cast
Material Lens
Polycarbonate (PC)
Mounting Brackets Iron
Accessories
Mounting Bracket (with screws), Screw driver for adjustment, Sensitivity adjuster, Instruction manual
Engineering Data (Reference Value)
Parallel Operating Range
Through-beam
4
Y
3
X
2
1
5
10
15
20
0
Distance X (m)
-1
-2
-3
-4
Excess Gain vs. Set Distance
Through-beam
100
70
50
30
10
7
5
3
Operation 1
Level
0
5
10
15
20
Distance X (m)
2