English
Language : 

E2KC25MY1 Datasheet, PDF (2/18 Pages) Omron Electronics LLC – Adjustable Long-distance Sensor
Ratings and Specifications
E2K-C
Standard Models
Item
Model
E2K-C25ME1
E2K-C25ME2
E2K-C25MY1
E2K-C25MY2
Sensing distance
*
25 mm
Sensing area
3 to 25 mm
Detectable object Conductors and dielectrics
Standard
sensing object
Grounded metal plate: 50 — 50 — 1 mm
Differential travel 15% max. of sensing sensing distance (when adjusted to 25 mm ”10% with standard sensing object)
Response
frequency
70 Hz
10 Hz
Power supply
voltage
(operating
voltage range)
12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max.
100 to 220 VAC (90 to 250 VAC), 50/60 Hz
Current
consumption
E Models: 10 mA max. at 12 VDC, 16 mA max. at 24 VDC
Leakage current
Y Models: 1 mA max. at 100 VAC (50/60 Hz) with output turned OFF, 2 mA max. at 200 VAC (50/60 Hz) with output turned
OFF
Con-
trol
out-
put
Load
current
Residual
voltage
200 mA max.
2 V max. (Load current: 200 mA, Cable length: 2 m)
5 to 200 mA (resistive load)
Refer to Engineering Data on page 4.
Indicators
Detection indicator (red)
Operation indicator (red)
Operation mode
(with sensing
object approach-
ing)
E1/Y1 Models: NO
E2/Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.
Protection
circuits
Reverse polarity protection, Surge suppressor
Surge suppressor
Ambient temper-
ature range
Operating/Storage: 25 to 70“C (with no icing or condensation)
Ambient
humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
”15% max. of sensing distance at 23“C in the temperature range of 10 to 55“C
”25% max. of sensing distance at 23“C in the temperature range of 25 to 70“C
Voltage influence
”2% max. of sensing distance at the rated voltage in rated
voltage ”15% range
”2% max. of sensing distance at the rated voltage in rated
voltage +20%, 10% range at 100 VAC, ”20% range at 200
VAC
Insulation
resistance
50 M: min. (at 500 VDC) between current-carrying parts and case
Dielectric
strength
1,000 VAC, 50/60 Hz for 1 min between current-carrying
parts and case
1,500 VAC, 50/60 Hz for 1 min between current-carrying
parts and case
Vibration
resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of
protection
IEC 60529 IP66
Connection
method
Pre-wired Models (Standard cable length: 2 m)
Weight
(packed state)
Approx. 200 g
Case
Mate-
rials Sensing
surface
Heat-resistant ABS
Accessories
Mounting Bracket, Instruction manual
* The set distances are sensing distances applicable to standard sensing objects. Refer to Engineering Data on page 4 for other materials.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.