Engineering Data
■ Field of View Characteristics
D6T-44L-06
Field of view in X Direction
Field of view in Y Direction
X view angle
44.2°
Y view angle
45.7°
Detection Area for Each Pixel
−
Y direction
P0
P1
+
P4
P5
P2
P3
+
P8
P6
P9
P7
P12
P10
P13
P11
X direction
P14
P15
−
Note: Definition of view angle: Using the maximum Sensor output as a reference, the angular range where the Sensor output is 50% or
higher when the angle of the Sensor is changed is defined as the view angle.
D6T-8L-06
Field of view in X Direction
X view angle
62.8°
Field of view in Y Direction
Y view angle
6°
Detection Area for Each Pixel
− Y direction
+
P0
+
P1
P2
P3
P4
X direction
P5
Note: Definition of view angle: Using the maximum Sensor output as a reference, the angular
range where the Sensor output is 50% or higher when the angle of the Sensor is
changed is defined as the view angle.
P6
P7
−
■ Object Temperature
Detection Range
55
50
45
40
35
30
25
20
15
10
5
0
−5
−5 0 5 10 15 20 25 30 35 40 45 50 55
Object temperature Tx (°C)
: Inspection point for accuracy 1
: Inspection point for accuracy 2
: Object temperature detection range
■ Connections
Thermal Sensor Configuration Diagram
Sensor element Amplifier
Digital processor
Pixel 0
Pixel 15
4. SCL
3. SDA
2. VCC
1. GND
Note: The 1×8 type has pixels 0 to 7.
Terminal Arrangement
Terminal
1
2
3
4
Name
GND
VCC
SDA
SCL
Function
Ground
Positive power supply
voltage input
Serial data I/O line
Serial clock input
Remarks
Connect the open-drain SDA
terminal to a pull-up resistor.
Connect the open-drain SCL
terminal to a pull-up resistor.
2
MEMS Thermal Sensors D6T