D2MC
D2MC
Characteristics
Item
D2MC-5j
D2MC-01j
Operating speed
1° to 360°/sec
Operating frequency
Mechanical: 240 operations/min
Electrical: 20 operations/min
Mechanical: 240 operations/min
Electrical: 60 operations/min
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
20 mΩ max. (initial value)
100 mΩ max. (initial value)
Dielectric strength
600 VAC, 50/60 Hz for 1 min between non-continuous terminals
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each
terminal and non-current-carrying metal part
Vibration resistance
Shock resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: D2MC-jE: 100 m/s2 (approx. 10G)
D2MC-jF: 100 m/s2 (approx. 10G)
D2MC-jH: 200 m/s2 (approx. 20G)
Life expectancy
Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min.
Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (1,000,000
operations at 0.1 A, 125 VAC/30 VDC)
Ambient temperature
Operating: –25°C to 80°C (with no icing)
Ambient humidity
Operating: 85% max.
Weight
Approx. 10.5 g
Note: All the models listed here are supplied without actuator lever. If an actuator lever is required, please order separately by indicating the
model name of the actuator lever.
See“Accessories”.
Approved Standards
UL (File No. E41515)
CSA (File No. LR21642)
D2MC-5j series: 5 A, 125 VAC
5 A, 250 VAC
D2MC-01j series: 0.5 A, 125 VAC
0.5 A, 30 VDC
Operating Characteristics
Model
OF max.
RF min.
PT max.
OT min.
MD min.
RT min.
TT min.
FP
D2MC-jE
0.5 mN S m (5.1 gf S cm)
0.05 mN S m (0.6 gf S cm)
21°
17°
3°
5°
38°
15±3°
D2MC-jF
0.75 mN S m (7.6 gf S cm)
0.09 mN S m (0.9 gf S cm)
D2MC-jH
1.0 mN S m (10.2 gf S cm)
0.13 mN S m (1.3 gf S cm)
139