English
Language : 

D2F Datasheet, PDF (2/8 Pages) Omron Electronics LLC – Snap Action Switch
Specifications
■ Characteristics
Operating speed
1 to 500 mm/second (pin plunger models)
Operating frequency
Mechanical: 200 operations per minute max.
Electrical: 30 operations per minute max.
Contact resistance
General Purpose: 30 mΩ max. (Standard force versions)
50 mΩ max. (Low force versions)
Microload:
100 mΩ max.
Insulation resistance
100 MΩ min. at 500 VDC
Dielectric strength (See note 2)
600 VAC, 50/60 Hz for 1 minute between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 minute between current-carrying metal parts and ground, and between each
terminal and non-current-carrying metal parts
Vibration resistance (See note 3) Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance (See note 3)
Destruction: 1,000 m/s2 (approx. 100G) max.
Malfunction: 300 m/s2 (approx. 30 g min.) max.
Degree of protection
IEC IP40
Degree of protection against
electric shock
Class I
Proof tracking index (PTI)
175
Ambient operating temperature
-25° to 65°C (at 60% RH) with no icing
Ambient operating Humidity
85% max. (for 5° to 35°C)
Service life
Mechanical: 1 million operations min. at 60 operations/minute.
(Consult Omron for test conditions) Electrical: 30,000 operations min. at 30 operations/minute.
Weight
Approx. 0.5 g (pin plunger models)
Note: 1. Data shown are of initial value.
2. The dielectric strength shown in the table indicates a value for models with a separator.
3. For pin plunger models, the values are measured at the free position and total travel position. For the lever models, they are measured
at the total travel position.
■ Ratings
Rated Voltage
125 VAC
30 VDC
Resistive load
Microvoltage/current (D2F-01 models)
Low force
Standard
—
—
0.1 A
0.1 A
General-purpose (D2F models)
Low force
Standard
1A
3A
0.5 A
2A
Note: 1. When using an inductive load or motor load, consult OMRON.
2. The ratings apply under the following test conditions: Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min.
■ Approvals
UL Recognized, CSA Certified
Rated voltage
125 VAC
30 VDC
D2F
Standard
Force
Low Force
3A
1A
2A
0.5 A
D2F-01
---
0.1 A
Note: The rated values approved by each of the safety standards
(e.g.UL,CSA) may be different from the performance character-
istics individually defined in this catalog.
■ Contact Specifications
Item
Specification
Material
Gap
(Standard value)
Minimum Applicable Load
(See note)
D2F
Crossbar
Silver alloy
0.25 mm
D2F-01
Gold alloy
100 mA at 5 VDC 1 mA at 5VDC
Note: Minimum applicable loads are indicated by N standard
reference values. This value represents the failure rate at a
60% (λ60) reliability level (JIS C5003).
The equation λ60=0.5 x 10-6/operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%.
32
Snap Action Switch D2F