English
Language : 

A22N-PS183 Datasheet, PDF (2/19 Pages) Omron Electronics LLC – Specifications Common to All
All A22/M22 Assemblies
All A22/M22 Assemblies
Incandescent Lamp
Rated voltage
6 VDC
14 VAC/DC
28 VAC/DC
130 VAC/DC
Transformer Lighting
Rated voltage
110 VAC
220 VAC
Rated current
200 mA
80 mA
40 mA
20 mA
Operational voltage
95 to 115 VAC
190 to 230 VAC
Operating voltage
5V
12 V
24 V
100 V
Applicable lamp (BA8S/13j gold)
LED Lamp (A22-24Aj)
J CHARACTERISTICS
Item
Allowable
operating
frequency
Mechanical
Electrical
Insulation resistance
Dielectric strength
Vibration resistance
(See note 2)
Shock
Mechanical
resistance
Malfunction
(See note 2)
Life
Mechanical
expectancy
Electrical
Ambient temperature
(See note 1 )
Ambient humidity
Degree of protection
Electric shock protection
class
Degree of contamination
Pushbutton switches
Emergency stop switches
Knob-type selector switches Key-type
selector
switch
Non-illuminated
models:
A22-F, A22-T,
A22-G,
A22-S, A22-C,
A22-D,
A22-H, A22-M
Illuminated
models:
A22L-T,
A22L-G,
A22L-H,
A22L-D,
A22L-C
Non-illuminated Illuminated
models: A22E models:
A22EL
Non-illuminated Illuminated
models: A22S models:
A22W
Non-illuminated
models: A22K
Momentary operation:
60 operations/min max.
30 operations/min max.
Manual release: 30 operations/min max.
Automatic release: 30 operations/min max.
30 operations/min max.
30 operations/min max.
100 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min between terminals of same polarity
2,500 VAC, 50/60 Hz for 1 min between terminals of different polarity and also between each terminal and
ground
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms)
1,000 m/s2
{100G}
1,000 m/s2
{100G}
1,000 m/s2
{100G} max.
600 m/s2
{60G} max.
Momentary operation:
5,000,000 operations min.
500,000 operations min.
Operating:
-20°C to 70°C
(-4°F to
158°F)
Storage:
-40°C to 70°C
(-40°F to
158°F)
Operating:
-20°C to
55°C
(-4°F to
131°F)
Storage:
-40°C to
70°C (-40°F
to 158°F)
Operating: 35% to 85%
IP65
Class II
1,000 m/s2 {100G}
250 m/s2 {25G} max.
Momentary operation:
300,000 operations min.
300,000
operations
min.
Operating:
-20°C to 70°C
(-4°F to
158°F)
Storage:
-40°C to 70°C
(-40°F to
158°F)
300,000
operations
min.
Operating:
-20°C to
55°C (-4°F
to 131°F)
Storage:
-40°C to
70°C (-40°F
to 158°F)
1,000 m/s2
{100G}
1,000 m/s2
{100G} max.
500,000
operations
min.
500,000
operations
min.
Operating:
-20°C to 70°C
(-4°F to
158°F)
Storage:
-40°C to 70°C
(-40°F to
158°F)
1,000 m/s2
{100G}
600 m/s2
{60G} max.
100,000
operations
min.
100,000
operations
min.
Operating:
-20°C to
55°C (-4°F
to 131°F)
Storage:
-40°C to
70°C (-40°F
to 158°F)
1,000 m/s2
{100G}
1,000 m/s2
{100G} max.
500,000
operations
min.
500,000
operations
min.
Operating:
-20°C to 70°C
(-4°F to
158°F)
Storage:
-40°C to 70°C
(-40°F to
158°F)
3 (IEC947-5-1)
Note: 1. With no icing or condensation.
2. Malfunction within 1 ms.
31