Amplifier Units
E3X-SD
Digital incident light level display or
digital threshold value display (red)
Display of contents of functions Digital threshold value adjustment
during operation
(UP/DOWN)
Teaching status
indication(orange)
Operation Selector
Use to switch between
Light-ON and Dark-ON
E3X-NA
Sensitivity indicator
8-turn sensitivity adjuster
Operation Indicator Light-ON and
Teaching Button
(Orange)
Dark-ON Indicator The sensitivity and threshold
Lock Lever
value can be set automatically.
Lock lever Incident level indicators
Operation Indicator
Operation Selector
Use to switch between
Light-ON and Dark-ON
Timer switch
ON: Timer function is ON.
OFF: Timer function is OFF.
Operating Procedure
E3X-SD
1 Sensitivity Setting
The sensitivity can be set with the UP and DOWN Keys similar
to using an adjuster knob. The sensitivity can also be easily
set by using the following two teaching functions.
2-1. Teaching with/without a Workpiece
Two points (one with the workpiece and the other without) are
detected, and the operating level is set to the midpoint.
Light level is also automatically set to the optimal value.
Operation description
Press the TEACH button with the workpiece.
Button/Key
TEACH
Press the TEACH button without the
workpiece.
TEACH
E3X-NA
1 Displays
A bar display (with four green and one red) showing excess
gain is provided in addition to the orange operation indicator.
Use these when adjusting the light axis and setting the
sensitivity at setup.
Display/indicator status (for L/ON)
Operation indicator
Excess gain
level
Description
Excess gain level display
Approx.
120% min.
Stable incident
light
Approx.
110% to 120%
2-2. Automatic Teaching
Changes within a time are detected, and the operating level is
set to the midpoint between the maximum and the minimum
values of the changes. This setting is optimal for when the
workpieces cannot be stopped. Execute automatic teaching
again if the incident light level is not automatically set to the
optimal value.
Operation description
Press the TEACH button for 3 s min. Let the
workpiece pass while the button is pressed.
Button/Key
TEACH
Approx.
90% to 110%
Unstable
incident light or
Unstable
interrupted light
Approx.
80% to 90%
Approx.
80% max.
Stable
interrupted light