English
Language : 

G3NA240BDC524 Datasheet, PDF (14/18 Pages) Omron Electronics LLC – Wide Lineup of General-purpose Solid State Relays with Applicable Loads of 5 to 90 A
High-capacity Heat Sink (Y92B-
P250NF)
DIN-track Mounting
• Assembled DIN Tracks are heavy. Mount the DIN Tracks securely.
Be sure that the Heat Sink is securely locked to the DIN Track.
• Attach End Plates (PFP-M, order separately) to both ends of the
Units on the DIN Track to hold them in place.
• To mount a Heat Sink to a DIN Track, press down at the point
indicated by arrow 1 in the diagram and then press in the Heat Sink
at the point indicated by arrow 2.
Vertical
Applicable DIN Track
Mounting is possible on TE35-15Fe (IEC 60715) DIN tracks. DIN
tracks from the following manufacturers can be used.
Manufacturer
Schneider
WAGO
PHOENIX
Thickness: 1.5 mm
AM1-DE2000
210-114 or 210-197
N35/15
Thickness: 2.3 mm
---
210-118
N35/15/15-2.3
Direct Mounting
• Prepare mounting holes as shown in the diagram.
Tightening torque: 0.98 to 1.47 N⋅m
64±0.3
130±0.3
Four, 4.5 dia. or M4 holes
• When mounting a Heat Sink directly, first remove the Fan Unit, then
mount the Heat Sink by itself before attaching the Fan Unit again.
(Remove the two screws shown in the following diagram.)
Remove screws Fan Unit
Heat Sink
• First, temporarily mount the Heat Sink with the bottom two screws
and then attach the top two screws with the mounting bracket
sandwiched between the Heat Sink and mounting surface. Finally,
tighten all four screws.
G3NA
Ratings and Characteristics of High-
capacity Heat Sink (Y92B-P250NF)
Fan Ratings
Rated voltage
Operating voltage
Frequency
Rated current
(See note.)
Rated speed
(See note.)
200 V
85% to 110% of rated voltage
50/60 Hz
0.061 A at 50 Hz
0.052 A at 60 Hz
2,600 r/min at 50 Hz
3,050 r/min at 60 Hz
Note: Average values.
Thermostat Ratings
Operating temperature Approx. 90°C
Contact ratings
3 A at 240 VAC, resistive load
3 A at 24 VDC, resistive load
Fan/Thermostat Characteristics
Motor type
Single-phase shading coil induction motor
(2-pole, open type)
Terminal type
Terminals
Insulation class IEC class B (130°C)
UL class A (105°C)
CSA class A (105°C)
Insulation
resistance
100 MΩ min. (at 500 VDC) between all power
supply connections and uncharged metal parts.
Insulation
2,000 VAC (1 minute) between all power supply
withstand voltage connections and uncharged metal parts.
Ambient operating −30 to 70°C (no icing)
temperature
Ambient storage −40 to 85°C (no icing)
temperature
Ambient humidity 25 to 85%
Protection
Impedance protection
Materials
Frame : Die-cast aluminum
Blades : Glass polycarbonate
Bearings
Ball bearings
Weight
Approx. 300 g
Compliant standards PSE, EN/IEC 60335 (CE marking compliant)
Certified standards UL/CSA (pending)
• Use a commercial power supply (50/60 Hz) for the Fan.
• Be sure to turn OFF the power supply and wait for the blades to
stop before inspecting the Fan.
• High-precision ball bearings are used in the fan and these may be
damaged if the Fan is dropped or otherwise subjected to shock.
The life and characteristics of the Fan will be reduced if the
bearings are damaged. Do not subject the Fan to shock.
• The life of the Fan depends on the ambient temperature, As a
guideline, the Fan life is 40,000 hours for continuous usage at
40°C.
• Be sure there are no objects near the air vents that would restrict
air flow and no loose objects, such as electrical lines.
• The Fan is an OMRON R87F-A4A-93HP (200 VAC) Fan. Use the
same model of Fan for replacement.
• The recommended tightening torque for the Fan is 0.44 N⋅m.
• Terminals equivalent to Faston #110 are used for the Fan power
supply terminals.
• Refer to the following table for the OMRON Fan power supply plug
cables (order separately).
Cable
length
1m
2m
UL certified
R87F-PC
R87F-PC-20
Complies with Electrical Appliance
and Material Safety Law (Japan)
R87F-PCJT
R87F-PCJT-20
• Connect the ground screw hole on the fan to PE.