English
Language : 

G3NA Datasheet, PDF (14/18 Pages) List of Unclassifed Manufacturers – Solid-state Relay
High-capacity Heat Sink
(Y92B-P250NF)
DIN-track Mounting
• Assembled DIN Tracks are heavy. Mount the DIN Tracks securely.
Be sure that the Heat Sink is securely locked to the DIN Track.
• Attach End Plates (PFP-M, order separately) to both ends of the
Units on the DIN Track to hold them in place.
• To mount a Heat Sink to a DIN Track, press down at the point indi-
cated by arrow 1 in the diagram and then press in the Heat Sink at
the point indicated by arrow 2.
Vertical
Applicable DIN Track
Mounting is possible on TE35-15Fe (IEC 60715) DIN tracks. DIN
tracks from the following manufacturers can be used.
Manufacturer
Schneider
WAGO
PHOENIX
Thickness: 1.5 mm Thickness: 2.3 mm
AM1-DE2000
---
210-114 or 210-197 210-118
N35/15
N35/15/15-2.3
Direct Mounting
• Prepare mounting holes as shown in the diagram. Tightening
torque: 0.98 to 1.47 N•m
64
130±0.3
• When mounting a Heat Sink directly, first remove the Fan Unit, then
mount the Heat Sink by itself before attaching the Fan Unit again.
(Remove the two screws shown in the following diagram.)
Remove screws Fan Unit
Heat Sink
• First, temporarily mount the Heat Sink with the bottom two screws
and then attach the top two screws with the mounting bracket sand-
wiched between the Heat Sink and mounting surface. Finally,
tighten all four screws.
Ratings and Characteristics of High-
capacity Heat Sink (Y92B-P250NF)
Fan Ratings
Rated voltage
Operating voltage
Frequency
Rated current
(See note.)
Rated speed
(See note.)
200 V
85% to 110% of rated voltage
50/60 Hz
0.085 A at 50 Hz
0.072 A at 60 Hz
2,500 r/min at 50 Hz
2,850 r/min at 60 Hz
Note: Average values.
Thermostat Ratings
Operating temperature Approx. 90°C
Contact ratings
3 A at 240 VAC, resistive load
3 A at 24 VDC, resistive load
Fan/Thermostat Characteristics
Insulation class
(Fan)
VDE:E (120°C)
UL: A (105°C)
CSA:B (130°C)
Protection class 1
Insulation
resistance
100 MΩ min. (at 500 VDC) between power sup-
ply connections and non-charged metal part
Dielectric strength Fan:
Thermostat:
2,000 VAC for 1 min
1,500 VAC for 1 min
Between power supply connections and non-
charged metal part
Ambient operating −30 to 70°C (with no icing)
temperature
Storage
temperature
−40 to 85°C (with no icing)
Ambient operating 25% to 85%
humidity
• Use a commercial power supply (50/60 Hz) for the Fan.
• Be sure to turn OFF the power supply and wait for the blades to
stop before inspecting the Fan.
• High-precision ball bearings are used in the fan and these may be
damaged if the Fan is dropped or otherwise subjected to shock.
The life and characteristics of the Fan will be reduced if the bear-
ings are damaged. Do not subject the Fan to shock.
• The life of the Fan depends on the ambient temperature, As a
guideline, the Fan life is 40,000 hours for continuous usage at 40°C.
• Be sure there are no objects near the air vents that would restrict
air flow and no loose objects, such as electrical lines.
• The tightening torque of the mounting screw when replacing the
Fan is 0.38 to 0.50 N•m.
• Terminals equivalent to Faston #110 are used for the Fan power
supply terminals.
• Connect the ground screw hole on the fan to PE.
464
Solid State Relay G3NA