Precautions
J CONNECTION
If the input/output lines of the photoelectric sensor are placed in the
same conduit or duct as power lines or high-voltage lines, the photo-
electric sensor could be induced to malfunction, or be damaged, by
the electrical noise. Either separate the wiring, or use shielded lines
as input/output lines to the photoelectric sensor.
The cord connected to the E3S-C can be extended up to 100 m pro-
vided that the diameter of each wire of the cord is 0.3 mm2 minimum.
J POWER SUPPLY
If the standard switching regulator is used as a power supply, the
frame ground (FG) terminal and the ground (G) terminal, on the
power supply, must be grounded. If this is not done the E3S-C may
malfunction, due to the switching noise of the power supply.
If an inverter motor or servomotor is used with the E3S-C, the frame
ground (FG) terminal and the ground (G) terminal, on the motor,
must be grounded, otherwise the E3S-C may malfunction.
J WATER RESISTANCE
To ensure the water resistance of the E3S-C, tighten the screws of
the operation panel cover to a torque of 3.5 to 5.5 kgf S cm (0.34 N S
m to 0.54 N S m).
Installation
J MOUNTING
Use M4 screws to mount the E3S-C. The tightening torque of each
screw must be 12 kgf S m (1.18 N S m) maximum.
J DIRECT MOUNTING
Mount the E3S-C as shown in the following illustrations.
Two, 4.5 dia.
through holes
M4
M4 hole
M4 hole
J OPTICAL AXIS OF THROUGH-BEAM
SENSOR
The E3S-C through-beam models incorporate two lenses, one of
which will be used as shown in the following illustration. When using
a slit, the slit must be on the side where the lens is located.
Lens in use. The slit
must be on this side.
Lens not in use.
Two, M3
M4 hole
M4 hole