2. Using the H8GN as a Timer
Typical Application Examples
• Setup Procedure
1. Changing Set Values
Power ON
Power ON
Set value and selections in each
display can be changed by pressing
the
and
Keys.
2. Display
Operation Level
No. 1 Display No. 2 Display
Typical Application Examples
Time range
0.0 to 999.9 s
Timer mode
DOWN (remaining time)
Output mode
A mode
Output time
Hold
Input signal width 20 ms
Initial Setting Level
Set Counter/Timer
selection
Set time range
Check timer mode
Use the
and
Keys to select the timer
function.
Use the
and
Keys to set the time range to
999.9 s
Use the
and
Keys to set the timer mode to
remaining time.
Check output mode Check the output mode.
Check output time Check the output time.
Check input signal Check the input signal width.
width
Set SV
Reset PV
Operation Level
Use the
and
Keys to set the SV to 10.0.
Press the
Key.
Present value (PV)/
set value (SV)
Press the Level Key for at
least 3 s. Operation stops.
Function:
Time range:
Timer mode:
Output mode:
Output time:
Input signal width:
Press the Level Key for at
least 1 s. Operation starts.
PV/SV:
PV:
Start operation
Operate
• Confirming Set Values
Set values are effective two seconds after key operation is stopped or when the
or
Key is pressed.
Preset Counter/Timer H8GN