5. Do not use wires with a damaged outer covering.
Otherwise, it may result in electric shock or ground
leakage.
6. Do not wire any wiring in the same duct or conduit as
power or high-tension lines. Otherwise, inductive noise
may damage the G3PF or cause it to malfunction.
(5) Adjustment and Use
Do not adjust or use the G3PF under the following conditions.
Doing so may result in damage, malfunction, or burning.
1. Conditions in which voltage or current exceeding the rated
values is applied to the input or output terminals.
2. Conditions in which a load exceeding the rated range is
selected or used.
3. Conditions in which a power supply frequency other than
the rated frequency is selected or used.
(6) Failure Detection
If the G3PF control circuit or alarm output circuit should
malfunction, the failure detection function and output will not
operate normally. To protect against this possibility, it is
recommended that the design includes redundant safety
functions.
(7) Noise and Surge Effects
If noise or an electrical surge occurs that exceeds the
malfunction withstand limit for the G3PF output circuit, the
output will turn ON for a maximum of one half cycle to absorb
the noise or surge. Confirm that turning the output ON for a
half cycle will not cause a problem for the device or system in
which the G3PF is being used prior to actual use. The G3PF
malfunction withstand limit is shown below.
• Malfunction withstand limit (reference value): 500 V
Note: This value was measured under the following conditions.
Noise duration:
100 ns and 1 µs
Repetition period: 100 Hz
Noise application time: 3 min
Precautions for Correct Use
The SSR in operation may cause an unexpected accident.
Therefore it is necessary to test the SSR under the variety of
conditions that are possible. As for the characteristics of the
SSR, it is necessary to consider differences in characteristics
between individual SSRs.
The ratings in this catalog are tested values in a temperature
range between 15°C and 30°C, a relative humidity range
between 25% and 85%, and an atmospheric pressure range
between 88 and 106 kPa. It will be necessary to provide the
above conditions as well as the load conditions if the user wants
to confirm the ratings of specific SSRs.
(1) Solvents
Do not allow the resin parts of the G3PF to come in contact
with solvents, such as alcohol, thinner, trichloroethane, or
gasoline. Doing so will dissolve markings and may result in
deteriorating the performance of the parts.
(2) Oil
Do not allow the terminal cover of the G3PF to come in contact
with oil. Doing so may cause the cover to become cloudy or to
crack.
(3) Mounting
Do not drop the G3PF or subject it to excessive vibration.
Doing so may result in damage, malfunction, or deterioration
of performance characteristics.
(4) Mounting Interval (Panel Mounting)
Note: When close mounting, check Load Current vs. Ambient Temperature
under Engineering Data.
Between duct and G3PF
Duct or other object blocking
airflow
G3PF-@25-@@@
80 mm min.
Mounting direction
Vertical
direction
80 mm min. Host and slave
G3PF-@35-@@@
80 mm min.
Between duct and G3PF
50 mm min.
11