English
Language : 

E2EL-1R5E12M Datasheet, PDF (11/12 Pages) Omron Electronics LLC – Cylindrical Proximity Sensor
E2EL
Item
AND
(serial
connection)
OR
(parallel
connection)
Examples
E2EL
Item
The Sensors connected together must satisfy the
following conditions:
iL + (N–1) x i = Upper–limit of control output of each
Sensor
VS – N x VR = Load operating voltage
N=
No. of Sensors
VR =
VS =
i=
Residual voltage of each Sensor
Supply voltage
Current consumption of the Sensor
iL =
Load current
If the MY Relay, which operate at 24 VDC, is used as a
load for example, a maximum of two Proximity Sensors
can be connected to the load.
The number of Sensors connected in parallel varies with
the Proximity Sensor model.
Effects of Surrounding Metal
Shielded types:
Shielded types allow direct installation on metal plates in an em-
bedded manner without performance change. A minimum distance
of 3sn is required between the active surface and a metallic surface
in front of the device. (Fig. 1).
For SUS shielded types the following minimum distances are re-
quired to avoid performance change (see Fig.2 and table below):
Shielded SUS Types
E2EL–C2j–DS
E2EL–X2j–DS
E2EL–X4j–DjS
E2EL–X8j–DjS
0,5 mm
0,5 mm
1,0 mm
2,0 mm
Free zone
w3sn
Non–shielded types:
Installation of non–shielded types in metal require the minimum di-
stances according to Fig. 3.
w3sn w2sn
d w3d
Fig.3: Non–shielded type
Fig.1: Shielded type (except SUS)
Freezone
w3sn
Fig.2: Shielded SUS type
11