English
Language : 

K3HB-H Datasheet, PDF (1/16 Pages) Omron Electronics LLC – Temperature Indicator
Temperature Indicator
K3HB-H
CSM_K3HB-H_DS_E_6_1
New High-speed, High-precision Temperature
Indicator
• Capable of high-speed sampling at 50 times per second (20 ms).
• High-resolution of 0.01°C with platinum-resistance thermometer
Pt100 input. Thermocouple sensor inputs also support a resolution of
0.1°C for all ranges.
• Temperature input shift is easily set using two points.
Display
Input
compensation
After
value 2
compensation
Input
compensation
value 1
Before
compensation
0
Input
Input
Input
compensation
compensation
input value 1
input value 2
• Series expanded to include DeviceNet models.
• UL certification approval (Certification Mark License).
• CE Marking conformance by third party assessment body.
• Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
Refer to Safety Precautions for All Digital Panel
Meters.
Model Number Structure
■ Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
Base Units with Optional Boards
K3HB-H@
15
1. Input Sensor Code
TA: Temperature input
Thermocouple input/Platinum-resistance thermometer input
5. Supply Voltage
100-240 VAC: 100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
Optional Boards
K3HB-H@-@@@
1 2 34 5
2. Sensor Power Supply/Output Type Code
None: None
CPA: Relay output (PASS: SPDT) + Sensor power supply
(12 VDC +/−10%, 80 mA) (See note 1.)
L1A: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power
supply
(12 VDC +/−10%, 80 mA) (See note 2.)
L2A: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power
supply (12 VDC +/−10%, 80 mA) (See note 2.)
A:
Sensor power supply (12 VDC +/−10%, 80 mA)
FLK1A: Communications (RS-232C) + Sensor power supply
(12 VDC +/−10%, 80 mA) (See note 2.)
FLK3A: Communications (RS-485) + Sensor power supply
(12 VDC +/−10%, 80 mA) (See note 2.)
Sensor Power Supply/Output Boards
3. Relay/Transistor Output Type Code
K33-@
None: None
C1: Relay contact (H/L: SPDT each)
2
C2: Relay contact (HH/H/LL/L: SPST-NO each)
Relay/Transistor Output Boards
T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
K34-@
3
BCD∗: BCD output + transistor output (NPN open collector: HH/H/PASS/
L/LL)
DRT: DeviceNet (See note 2.)
Event Input Boards
K35-@
4
∗ A Special BCD Output Cable (sold separately) is required.
4. Event Input Type Code
None: None
1:
5 inputs (M3 terminal blocks), NPN open collector
2:
8 inputs (10-pin MIL connector), NPN open collector
3:
5 inputs (M3 terminal blocks), PNP open collector
4:
8 inputs (10-pin MIL connector), PNP open collector
Note: 1. CPA can be combined with relay outputs only.
2. Only one of the following can be used by each Digital Indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
Accessories (Sold Separately)
Rubber Packing
K32-DICN: Special Cable (for event inputs, with 8-pin connector)
K32-BCD: Special BCD Output Cable
Model
K32-P1
Note: Rubber packing is provided with the Controller.
1