General-purpose Limit Switch
HL-5000
Economical, Miniature Limit Switch Boasting
Rigid Construction
• The Head, Box, and Cover mate with ridged surfaces to maintain
strength.
• A unique Head structure provides a large OT for smooth operation.
• Easy-to-wire conduit opening design.
• Ideal for application in printing machines, forming machines, and light
machines.
(High Switches with high sealing characteristics, such as WL or D4C
Switches, in locations subject to oil, water, or precipitation.)
• Models with grounding terminals conform to the CE marking.
• Approved by CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Be sure to read Safety Precautions on page 4 to 5 and
Safety Precautions for All Limit Switches.
CSM_HL-5000_DS_E_3_1
Model Number Structure
Model
Number
Legend
(Not all combinations are possible. Ask
your OMRON representative for details.)
åH`LH-L5-@5Å@†Å†
(1)(2)
(1) Actuators
000: Roller lever
030: Adjustable roller lever
050: Adjustable rod lever
100: Sealed plunger
200: Sealed roller plunger
300: Coil spring
(2) Ground Terminal Specifications
Blank : Without ground terminal
G : With ground terminal/M5 tapping on the rear side
Ordering Information
Actuator
Roller lever
Model
HL-5000 *
Adjustable
roller lever
Adjustable
rod lever
Sealed
plunger
Sealed roller
plunger
HL-5030 *
HL-5050 *
HL-5100 *
HL-5200
Coil spring
HL-5300
* HL-5000 Limit Switches are offered with a choice of ground terminal/M5
tapping on the rear side conforming to various standards. When placing an
order, add the code to the model number to indicate if ground terminal/M5
tapping on the rear side is required.
-G: with ground terminal/M5 tapping on the rear side.
Specifications
Approved Standards
Agency
CCC (CQC)
Standard
GB14048.5
File No.
2003010303077624
Note: Ask your OMRON representative for information on approved models.
Ratings
Non-inductive load (A)
Inductive load (A)
Rated
voltage
Resistive
load
Lamp load
Inductive
load
Motor load
NC NO NC NO NC NO NC NO
125 VAC
5
1.5 0.7
250 VAC
5
1
0.5
3
2
1
3
1.5 0.8
12 VDC
5
3
4
3
24 VDC
5
3
4
3
125 VDC 0.4 0.2
−
−
−
250 VDC 0.4 0.2
−
−
−
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Inrush NC
current NO
24 A max.
12 A max.
Approved Standard Ratings
CCC (GB14048.5)
Applicable category and ratings
AC-15 3 A/250 VAC