English
Language : 

G6H Datasheet, PDF (1/8 Pages) Omron Electronics LLC – Ultra-compact, Ultra-sensitive DPDT Relay
PCB Relay
G6H
Ultra-compact, Ultra-sensitive DPDT
Relay
■ Compact size and low 5-mm profile.
■ Low power consumption (140 mW for single-side
stable, 100 to 300 mW for latching type) and high
sensitivity.
■ Low thermoelectromotive force.
■ Low magnetic interference enables high-density
mounting.
■ Single- and double-winding latching types also
available.
RoHS Compliant Refer to pages 16 to 17 for details.
Ordering Information
RC
DPDT
Classification
Fully
sealed
PCB terminal
Surface mount terminal
Single-side stable
G6H-2
G6H-2F
Single-winding latching
G6HU-2
---
Double-winding latching
G6HK-2
---
Note: When ordering, add the rated coil voltage to the model number.
Example: G6HK-2 12 VDC
Rated coil voltage
Model Number Legend
G6H -
-
VDC
1 2 34 5
1. Relay Function
None: Single-side stable
U: Single-winding latching
K: Double-winding latching
2. Contact Form
2: DPDT
3. Terminal Shape
None: PCB terminal
F: Surface mount terminal
4. Classification
U: Ultrasonically cleanable
5. Rated Coil Voltage
3, 5, 6, 9, 12, 24 VDC
Specifications
■ Coil Ratings
Single-side Stable Type (G6H-2, G6H-2F)
Rated voltage
Rated current
Coil resistance
Coil inductance Armature OFF
(H) (ref. value)
Armature ON
Must operate voltage
Must release voltage
Max. voltage
Power consumption
3 VDC
5 VDC
6 VDC
46.7 mA 28.1 mA 23.3 mA
64.3 Ω
178 Ω
257 Ω
0.025
0.065
0.11
0.022
0.058
0.09
75% max. of rated voltage
10% min. of rated voltage
200% of rated voltage at 23°C
Approx. 140 mW
9 VDC
15.5 mA
579 Ω
0.24
0.20
12 VDC
11.7 mA
1,028 Ω
0.43
0.37
24 VDC
8.3 mA
2,880 Ω
1.2
1.0
48 VDC
5.8 mA
8,228 Ω
---
---
170% of rated 140% of rated
voltage at 23°C voltage at 23°C
Approx.
200 mW
Approx.
280 mW
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C with a tolerance of ±10%.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. The maximum voltage that can be be applied when using the G6H-2F (at 85°C) is 115% (3 to 12 V) or 105% (24 V) of the rated
voltage.
63