English
Language : 

G6E Datasheet, PDF (1/8 Pages) Omron Electronics LLC – Low Signal Relay
Low Signal Relay
G6E
Subminiature, Sensitive Signal Relay
• Subminiature 7.87 H x 9.91 W x 16 L mm.
• High sensitivity with pick-up coil power of 98 mW.
• Surge withstand voltage meets FCC Part 68 requirements.
• Unique moving loop armature reduces relay size, magnetic
interference, and contact bounce time.
• Bifurcated crossbar contact assures high reliability.
• Single and Dual coil latching versions available.
• Fully sealed construction.
• RoHS Compliant.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6E-134P-ST-US-DC6).
RC
SPDT
Contact form
Bifurcated crossbar
Terminal style
Straight
Self-clinching
Model Number Legend
G6E -
- - DC
1 234 56 7 8
9
Standard
G6E-134P-US
G6E-134C-US
Model
Single coil latching Dual coil latching
G6EU-134P-US
G6EK-134P-US
G6EU-134C-US
G6EK-134C-US
1. Relay Function
None: Single-side stable
U: Single-winding latching
K: Double-winding latching
2. Contact Form
1:
SPDT
3. Contact Type
5. Terminals
3: Bifurcated crossbar
P: Straight PCB
Ag (Au-Alloy) contact C: Curved tail
7. Standoff dimension
Blank: 0.3 mm
ST: 0.64 mm
4. Enclosure Ratings
4: Fully sealed
6. Special Function
8. Approved Standards
L: Low sensitivity coil (400 mW) US: UL, CSA certified
9. Rated Coil Voltage
3, 5, 6, 9, 12, 24, 48 VDC
Specifications
■ Contact Data
Load
Resistive load (p.f. = 1)
Rated load
0.40 A at 125 VAC, 2 A at 30 VDC
Contact material
Ag (Au clad)
Carry current
3A
Max. operating voltage
250 VAC, 220 VDC
Max. operating current
3A
Max. switching capacity
50 VA, 60 W
Min. permissible load (See note) 10 µA, 10 mVDC
Inductive load (p.f. = 0.4) (L/R = 7 ms)
0.20 A at 125 VAC, 1 A at 30 VDC
25 VA, 30 W
Note: P level: λ60 = 0.1 x 10–6/operation
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary
depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions.
Low Signal Relay G6E
89