G5CA-1A-E-DC12 Datasheet, PDF (1/4 Pages) Omron Electronics LLC – Flat Relays that Switch 10A/15A Loads Power | |||
|
G5CA
PCB Power Relay
Flat Relays that Switch
10A/15A Loads Power
⢠Ideal for switching power in household appliances or for
outputs from industrial devices.
⢠Subminiature dimensions: 16 à 22 à 11 mm (L à W à H).
⢠High-sensitivity models available with low power
consumption (150 mW).
⢠Standard model conforms to UL/CSA standards.
⢠Fully sealed models are available
⢠Quick-connect terminal models are also available (#187
load contact terminals).
RoHS Compliant
â Model Number Legend
â Application Examples
G 5 C A - 1âAâ @â -@â -@â - @â
⢠Small home appliances
1234 5
1. Number of Poles
4. Classification
1A: 1-pole/SPST-NO (1a)
2. Enclosure rating
None: Standard
E: High-capacity
G
5
None: Flux protection
5. Coil consumption
C
4: Fully sealed
None: Standard
A
3. Terminal Shape
H: High-sensitivity
None: PCB terminals
TP: Quick-connect
terminals (#187)
â Ordering Information
Enclosure
rating
Item
Contact form Model
Flux
protection
Fully
sealed
SPST-NO
(1a)
G5CA
-1A
G5CA
-1A4
â Rarings
Standard
Rated coil Minimum
voltage packing unit
5 VDC
12 VDC
24 VDC
5 VDC
20 pcs/tube
12 VDC
24 VDC
Model
G5CA
-1A-H
G5CA
-1A4-H
High-sensitivity
Rated coil Minimum
voltage packing unit
5 VDC
12 VDC
24 VDC
5 VDC
20 pcs/tube
12 VDC
24 VDC
High-capacity
Quick-connect terminals (#187)
Model
Rated coil
voltage
Minimum
packing unit
Model
Rated coil Minimum
voltage packing unit
G5CA
-1A-E
5 VDC
12 VDC
24 VDC
20 pcs/tube
G5CA
-1A-TP-E
5 VDC
12 VDC
24 VDC
20 pcs/tube
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5CA-1A 5 VDC
Rated coil voltage
Note 2. Contact your OMRON representative for details on other coil
voltage specifications.
Note 3. High-capacity models with a fully sealed structure are not available.
Note 4. Standard or high-sensitivity models with quick-connect
terminals are not available.
âCoil
Classification
Standard,
high-capacity,
or quick-connect
terminals
High-sensitivity
Item
Rated voltage
5 VDC
12 VDC
24 VDC
Rated current
(mA)
40
16.7
8.3
Coil resistance
(Ω)
125
720
2,880
Must-operate voltage
(V)
75% max.
5 VDC
12 VDC
24 VDC
30
12.5
6.25
167
960
3,840
80% max.
Must-release voltage
Max. voltage
(V)
(V)
% of rated voltage
150% (standard)/
10% min.
130% (high-capacity,
quick-connect terminals)
(at 23°C)
10% min.
150%
(at 23°C)
Power consumption
(mW)
Approx. 200
Approx. 150
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The âmaximum voltageâ is the maximum voltage that can be applied to the relay coil.
âContacts
Classification
Item
Load
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Standard
Resistive load
Inductive load
(cosÏ = 0.4, L/R = 7 ms)
10 A at 250 VAC; 3 A at 250 VAC;
10 A at 30 VDC 3 A at 30 VDC
10 A
10 A
High-sensitivity
Resistive load
Inductive load
(cosÏ = 0.4, L/R = 7 ms)
Single
Ag-alloy (Cd free)
10 A at 250 VAC; 3 A at 250 VAC;
10 A at 30 VDC 3 A at 30 VDC
10 A
250 VAC, 125 VDC
10 A
High-capacity, or quick-connect terminals
Resistive load
Inductive load
(cosÏ = 0.4, L/R = 7 ms)
15 A at 110 VAC; 5 A at 110 VAC;
10 A at 30 VDC 3 A at 30 VDC
15 A
15 A
1
|
▷ |