English
Language : 

EY3A-1051 Datasheet, PDF (1/2 Pages) Omron Electronics LLC – Single Beam Sensor (1 Beam: 50 mm)
Single Beam Sensor (1 Beam: 50 mm)
EY3A-1051
■ Dimensions
Note: All units are in millimeters unless otherwise indicated.
Positioning boss
Center of detector
7.9 dia.
Center of emitter
Pin no. 1
8.3 dia.
3.2+-00.2 dia.
8 dia.
3+-00.2 dia.
Pin no. Remarks Name
1
O
2
V
Output (OUT)
Power supply
(Vcc)
3
G
Ground (GND)
Unless otherwise specified, the
tolerances are as shown below.
Dimensions
3 mm max.
3 < mm ≤ 6
6 < mm ≤ 10
10 < mm ≤ 18
18 < mm ≤ 30
30 < mm ≤ 50
Tolerance
±0.3
±0.375
±0.45
±0.55
±0.65
±0.8
Recommended Mating Connectors:
Japan Molex 51090-0300 (crimp connector)
52484-0310 (press-fit connector)
■ Features
• Ensures higher sensitivity and external light interference resistivity
than any other photomicrosensor.
• Narrow sensing range ensures stable sensing of a variety of
sensing objects.
■ Absolute Maximum Ratings (Ta = 25° C)
Item
Power supply voltage
Load voltage
Load current
Ambient
temperature
Operating
Storage
Symbol
VCC
VOUT
IOUT
Topr
Tstg
Rated value
7V
7V
10 mA
0° C to 60° C
–15° C to 70° C
Note: Make sure there is no icing or condensation when operating the
Sensor.
■ Ordering Information
Description
Single beam sensor
Model
EY3A-1051
■ Electrical and Optical Characteristics (Ta = 0° C to 60° C)
Item
Power supply voltage
Current consumption
Peak current consumption
Low-level output voltage
High-level output voltage
Response delay time (high to low)
Response delay time (low to high)
Value
5 V ±5%
50 mA max.
200 mA max.
0.6 V max.
3.5 V min.
1.5 ms max.
1.5 ms max.
Condition
---
VCC = 5 V, RL = ∞
VCC = 5 V, RL = ∞
VCC = 5 V, IOL = 4 mA (see note 1)
VCC = 5 V, RL = 4.7 kΩ (see note 2)
The time required for the output to become “Lo” after placing
sensing object.
The time required for the output to become “Hi” after removing
sensing object.
Note: 1. These conditions are for the sensing of lusterless paper with an OD of 0.9 maximum located at the correct sensing position of the Sensor
as shown in the optical path arrangement on the next page.
2. These conditions are for the sensing of the paper supporting plate with an OD of 0.05 located using the glass plate without paper as
shown in the optical path arrangement on the next page.
128
Single Beam Sensor (1 Beam: 50 mm) EY3A-1051