English
Language : 

D6F-V03A1 Datasheet, PDF (1/4 Pages) Omron Electronics LLC – MEMS Flow-Sensor
MEMS Flow-Sensor
D6F-V03A1
The unique dust separating structure,
developed by OMRON is a compact and
highly efficient FLOW-SENSOR.
• A dust-resistant design has been taken into consideration,
by the original dust segregation structure, of OMRON.
• +/-10% Full-Scale repeatable accuracy achieves consistent
air velocity measurement.
• Applications include clogged-filter detection and air velocity.
Sensor specification
Type
D6F-V03A1
Flow Range
0 – 3 m/s @ 25° C, 1 atmosphere
Case Material
Thermoplastic resin
Gas
Air
Ambient Temperature
-10 to +60° C (with no condensation)
Using Humidity
Max. 85% RH (with no condensation)
Storage Temperature
-40 to +80° C (with no condensation)
Preservation Humidity
Max. 85% RH (with no condensation)
Power Supply Voltage
3.15 to 3.45 VDC
Output Signal
Analog output 0.5 to 2 VDC (non-linear output)
Load resistance min. 10kΩ
Current Consumption
Max. 15mA (No-load, VCC = 3.3 VDC, 25° C)
Insulation Resistance
20Mohm min. (500VDC, between lead terminal and the case)
Dielectric Withstanding Voltage Leakage current is 1mA max. (at 500 VAC, 50/60Hz for one minute).
500VAC, 50/60Hz judged at 1mA max. (between the lead terminals and the case)
Absolute maximum rating
Item
Power supply voltage
Output voltage
Symbol
VCC
VOUT
Rating
12.0
3.0
Unit
VDC
VDC
Output characteristic
Flow Velocity (m/sec)
Output Voltage (VDC)
0
0.50
±0.15
0.75
0.70
±0.15
1.50
1.11
±0.15
2.25
1.58
±0.15
Measurement condition: Power-supply voltage 3.3VDC, ambient temperature 25° C and dry air.
Note: 1. Air velocity is the value converted from the mass-flow in OMRON regulation wind tunnel phi48mm.
2. The air velocity, set to the Measurement Law, is not shown. Please confirm in a real use environment in use.
3. Temperature characteristics:
Over ambient temperature range -10 to +60° C: within ±20% F.S. of detected characteristics
Of at +25° C.
3.00
2.00
±0.15
MEMS Flow-Sensor D6F-V03A1