English
Language : 

A22E-M-02B Datasheet, PDF (1/21 Pages) Omron Electronics LLC – Install in 22-dia. or 25-dia. Panel Cutout
Emergency Stop Switch
A22E
Install in 22-dia. or 25-dia. Panel Cutout
• Direct opening mechanism to open the circuit when the contact
welds → .
• Safety lock mechanism prevents operating errors.
• Easy mounting and removal of Switch Blocks using a lever.
• Mount three Switch Units in series to improve wiring efficiency
(with non-lighted Switch Units, three Units can be mounted for
multiple contacts).
• Finger protection mechanism on Switch Unit provided as a
standard feature.
• Install using either round, or forked crimp terminals.
• Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models)
Note: Be sure to read the precautions for all pushbutton switches in the
Pushbutton Switches Group Catalog (Cat. No. X018), as well as
the “Safety Precautions” on page 19.
Features
Safety Lock Mechanism to Prevent Misuse Construction
Lock position
This Switch enables emergency stops only when the pushbutton is
pressed intentionally and firmly.
Even if an object or person touches the pushbutton by mistake, the
contact will not be released unless the pushbutton reaches the lock
position.
This Switch uses a finger protection
mechanism to prevent electrical shocks.
Moreover, it is provided with a mechanism
to prevent terminal screws from coming
off and also allows connection to either
round or forked crimp terminals.
Finger protection
Mechanism for
preventing
terminal screws
from coming off
(loosening the
screws do not
cause them to
come off)
Operation
Unit
Color: Red
Non-lighted
Lighted
Lamp
Light source
• LED Lamp
• Incandescent Lamp
½
°
Switch
°
°
Contact Ratings
°
¾ 10 A at 110 VAC (resistive load)
°
°
10 A at 24 VDC (resistive load)
°
°
Lighting Method
¿
Non-lighted
Lighted (without Voltage Reduction
(The above figures are
Unit)
examples of the lighted model.)
Lighted (with Voltage Reduction Unit)
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
1