English
Language : 

CRE-10201 Datasheet, PDF (1/1 Pages) Okaya Electric America, Inc. – SPARK QUENCHER
CRE, 3CRE, 6CRE SERIES
SPARK QUENCHER
Features
● Broad use in industrial applications.
● External mounting tab.
● 1/2 watt non-inductive, high pulse resistor.
● Three phase delta connection (3 CRE). Three
phase three line (6 CRE).
Applications
● Automatic machines and industrial machinery.
● Model numbering system
CRE
Supported Series
number name
None 1 Phase
3 3 Phase
6
3 Phase
3 Line
Capacitance Resistance
10 0.1μF
20 0.2μF
30 0.3μF
50 0.5μF
201 200Ω
151 150Ω
680 68Ω
500 50Ω
The combination of Resistance and Capacitance is shown in following chart.
● Dimensions
CRE
φ 4.3
3CRE
φ 4.3
UL
VDE
Safety Standard
:UL1283
:IEC/EN 60384-14: 2005
File No.
E78644
128527
CRE Series
6CRE
φ 4.3
3CRE (3 Phase)
6CRE (3 Phase)
Soldering
F±1
UL-1015
F±3 F±3
(AWG18)
3
Soldering
UL-1015
(AWG18)
3±0.5
Soldering
UL-1015
(AWG18)
3±0.5
15
W±1
22
W±1
● Circuit
22
W±1
Unit: mm
CRE
3CRE
6CRE
Electrical Specifications
Rated Voltage 250VAC
Safety
Model
Standard Class Number
Capacitance
μF±20%
Resistance
Ω±30%
Dimensions
WH T F
Pulse condition (max.)
Peak
to
Pulse
width
peak
Repetitive
frequency
Pulse width
(sec) x
Frequency(Hz)
Peak
Pulse
Voltage
Test
Voltage
Insulation
Resistance
CRE-10201
0.1
200(1/2W)
0.45
Line to Line Line to Line
23 26 14 13
50msec.
CRE-20151
0.2
150(1/2W)
0.15
625VAC 10,000MΩ
CRE-30680
0.3
68(1/2W)
0.1
50/60Hz 60sec min.
X2 CRE-50500
0.5
50(1/2W)
25 32 16
700V
15
360Hz.
0.07
800V
max.
3CRE-30680* 0.3/1 phase 68 (1/2W) /1 phase
70msec.
0.1
Line to Case Line to Case
44
3CRE-50500
0.5
50(1/2W)
35 26
2,000VAC 100,000MΩmin.
0.07
6CRE-50500 /1 phase
/1 phase 48
-
50/60Hz 60sec (at 500VDC)
* 3CRE-30680 is not UL approved.
Operating Temperature: -40~+85°C
60