8.1.4 Command: charge-pump-ctrl
The charge-pump-ctrl command enables or disables the internal VLCD generation and
controls the charge pump voltage multiplier setting.
Table 9. Charge-pump-ctrl - charge pump control command bit description
Bit
Symbol
Value
Description
7 to 2 -
1100 00
fixed value
1
CPE
charge pump switch
0[1]
charge pump disabled;
no internal VLCD generation;
external supply of VLCD
1
charge pump enabled
0
CPC
charge pump voltage multiplier setting
0[1]
VLCD = 2  VDD2
1
VLCD = 3  VDD2
[1] Default value.
8.1.5 Command: temp-msr-ctrl
The temp-msr-ctrl command enables or disables the temperature measurement block and
the temperature compensation of VLCD.
Table 10. Temp-msr-ctrl - temperature measurement control command bit description
For further information, see Section 8.4.8 on page 38.
Bit
Symbol
Value
Description
7 to 2 -
1100 10
fixed value
1
TCE
temperature compensation switch
0
no temperature compensation of VLCD
possible
0
TME
1[1]
temperature compensation of VLCD possible
temperature measurement switch
0
temperature measurement disabled;
no temperature readout possible
1[1]
temperature measurement enabled;
temperature readout possible
[1] Default value.
8.1.6 Command: set-VPR-MSB and set-VPR-LSB
With these two instructions, it is possible to set the target VLCD voltage for the internal
charge pump, see Section 8.4.3 on page 33.
Table 11. Set-VPR-MSB - set VPR MSB command bit description
Bit
Symbol
Value
Description
7 to 4 -
0100
fixed value
3 to 0 VPR[7:4]
0000[1] to 1111 the four most significant bits of VPR[7:0]