English
Language : 

74HCT4067DB Datasheet, PDF (15/30 Pages) NXP Semiconductors – 16-channel analog multiplexer/demultiplexer
NXP Semiconductors
74HC4067; 74HCT4067
16-channel analog multiplexer/demultiplexer
Table 9. Dynamic characteristics 74HC4067 …continued
GND = 0 V; tr = tf = 6 ns; CL = 50 pF unless specified otherwise; for test circuit see Figure 14.
Vis is the input voltage at a Yn or Z terminal, whichever is assigned as an input.
Vos is the output voltage at a Yn or Z terminal, whichever is assigned as an output.
Symbol Parameter
Conditions
25 C
Typ
Max
ton
turn-on time
E to Yn; see Figure 13
VCC = 2.0 V
VCC = 4.5 V
VCC = 5.0 V; CL = 15 pF
VCC = 6.0 V
VCC = 9.0 V
Sn to Yn
VCC = 2.0 V
VCC = 4.5 V
VCC = 5.0 V; CL = 15 pF
VCC = 6.0 V
VCC = 9.0 V
E to Z
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 9.0 V
Sn to Z
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 9.0 V
CPD
power dissipation per switch; VI = GND to VCC
capacitance
[4]
80
275
29
55
26
-
23
47
17
42
88
300
32
60
29
-
26
51
18
45
85
275
31
55
25
47
18
42
94
300
34
60
27
51
19
45
[5] 29
-
40 C to +125 C Unit
Max Max
(85 C) (125 C)
345
415 ns
69
83 ns
-
- ns
59
71 ns
53
63 ns
375
450 ns
75
90 ns
-
- ns
64
77 ns
56
68 ns
345
415 ns
69
83 ns
59
71 ns
53
63 ns
375
450 ns
75
90 ns
64
77 ns
56
68 ns
-
- pF
[1] tpd is the same as tPHL and tPLH.
[2] Due to higher Z terminal capacitance (16 switches versus 1) the delay figures to the Z terminal are higher than those to the Y terminal.
[3] ton is the same as tPHZ and tPLZ.
[4] toff is the same as tPZH and tPZL.
[5] CPD is used to determine the dynamic power dissipation (PD in W).
PD = CPD  VCC2  fi + {(CL + Csw)  VCC2  fo} where:
fi = input frequency in MHz;
fo = output frequency in MHz;
{(CL + Csw)  VCC2  fo} = sum of outputs;
CL = output load capacitance in pF;
Csw = switch capacitance in pF;
VCC = supply voltage in V.
74HC_HCT4067
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 5 — 13 December 2011
© NXP B.V. 2011. All rights reserved.
15 of 30