TDA3681A
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
Temperature protection
Tj(sd)
junction temperature for
shutdown
Tj(hold)
junction temperature for
hold trigger
150 160
170
°C
150 160
170
°C
Notes
1. Minimum operating voltage, only if VP1 has exceeded 6.5 V.
2. The total quiescent current is measured in the standby mode. Therefore, the enable inputs of regulators 1, 3, 4 and
the power switch are grounded and RL(REG2) = ∞ (see Fig.8).
3. The voltage of the regulator drops as a result of a VP1 drop for regulators 1 and 2. Regulators 3 and 4 drop as a result
of VP2 drop.
4. The rise and fall times are measured with a 10 kΩ pull-up resistor and a 50 pF load capacitor.
5. The delay time depends on the value of the reset delay capacitor: td(RES) = I--Cc---h- × VC(th) = C × (750 × 103)[s]
6. The delay time depends on the value of the reset delay capacitor: td(SW) = I--Cc---h- × VC(th) = C × (375 × 103)[s]
7. The drop-out voltage of regulators 1 and 2 is measured between pins VP1 and REGn. The drop-out voltage of
regulators 3 and 4 is measured between pins VP2 and REGn.
8. At current limit, Im(REGn) is held constant (see Fig.6).
9. The foldback current protection limits the dissipated power at short-circuit (see Fig.6).
10. The drop-out voltage is measured between pins BU and REG2.
11. The drop-out voltage of the power switch is measured between pins VP1 and SW.
12. The maximum output current of the power switch is limited to 1.8 A when the supply voltage exceeds 18 V.
13. At short-circuit, Isc(SW) of the power switch is held constant to a lower value than the continuous current after a delay
of at least 10 ms (see Fig.7).
2003 Aug 29