English
Language : 

NTE3007 Datasheet, PDF (2/3 Pages) NTE Electronics – Discrete LED Indicators
Electro–Optical Characteristics: (TA = +25°C unless otherwise specified)
Parameter
Symbol Test Conditions Min Typ Max Unit
Forward Voltage
NTE3007
NTE3008, NTE3010, NTE3011
VF IF = 20mA
– 1.7 2.0 V
– 2.1 2.8 V
NTE3009
– 2.0 2.8 V
Reverse Current
Luminous Intensity
NTE3007
NTE3008
IR VR = 5V
– – 100 µA
IV IF = 10mA, Note 1 0.3 0.8 – mcd
0.4 1.1 – mcd
NTE3009
0.8 3.5 – mcd
NTE3010, NTE3011
0.8 3.8 – mcd
Peak Emission Wave Length
NTE3007
NTE3008
λP Measurement
@ Peak
– 655 – nm
– 697 – nm
NTE3009
– 630 – nm
NTE3010
– 565 – nm
NTE3011
– 585 – nm
Spectral Line Half Width
NTE3007
∆λ
– 24 – nm
NTE3008
– 90 – nm
NTE3009
– 40 – nm
NTE3010
– 30 – nm
NTE3011
– 35 – nm
Viewing Angle
Capacitance
NTE3007
NTE3008
2q1/2 Note 2
– 72 – deg.
C VF = 0, f = 1MHz – 30 – pF
– 55 – pF
NTE3009
– 20 – pF
NTE3010
– 35 – pF
NTE3011
– 15 – pF
Note 1. Luminous intensity is measured with a light sensor and filter combination that approximates
the CIE (Commission Internationale De L’Eclairage) eye–response curve.
Note 2. Viewing Angle is the off–axis angle at which the luminous intensity is half the axial luminous
intensity.