English
Language : 

NTE6087 Datasheet, PDF (1/2 Pages) NTE Electronics – Schottky Barrier Silicon Rectifier
NTE6087
Schottky Barrier Silicon Rectifier
Features:
D Guarding for Stress Protection
D Low Forward Voltage
D +150°C Operating Junction Temperature
D Guaranteed Reverse Avalanche
Absolute Maximum Ratings:
Peak Repetitive Reverse Voltage, VRRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45V
Working Peak Reverse Voltage, VRWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45V
DC Blocking Voltage, VR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45V
Average Rectified Forward Current (VR = 45V, TC = +130°C), IF(AV) . . . . . . . . . . . . . . . . . . . . . . . 30A
Peak Repetitive Forward Current, IFRM
(Per Diode Leg, VR = 45V, Square Wave, 20kHz, TC = +130°C) . . . . . . . . . . . . . . . . . . . . 30A
Non–Repetitive Peak Surge Current, IFSM
(Per Diode Leg, Surge applied at rated load conditions halfwave, single phase, 60Hz) . . . . 150A
Peak Repetitive Reverse Surge Current (2µs, 1kHz), IRRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1A
Voltage Rate of Change (VR = 45V), dv/dt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000V/µs
Operating Junction Temperature Range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65° to +150°C
Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65° to +175°C
Maximum Thermal Resistance, Junction–to–Case (Per Diode Leg), RthJC . . . . . . . . . . . . . 1.5°C/W
Electrical Characteristics: (Per Diode Leg)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Instantaneous Forward Voltage
Instantaneous Reverse Current
vF iF = 30A, TC = +125°C, Note 1 –
iF = 30A, TC = +25°C, Note 1
–
iR VR = 45V, TC = +125°C, Note 1 –
VR = 45V, TC = +25°C, Note 1 –
– 0.73 V
– 0.82 V
– 40 mA
– 0.2 mA
Note 1. Pulse test: Pulse Width = 300µs, Duty Cycle ≤ 2%.