English
Language : 

NTE5640 Datasheet, PDF (1/2 Pages) NTE Electronics – TRIAC, 2.5A
NTE5640 thru NTE5643
TRIAC, 2.5A
Absolute Maximum Ratings:
Repetitive Peak Off–State Voltage (Gate Open, TJ = +100°C, Note 1), VDROM
NTE5640 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100V
NTE5641 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200V
NTE5642 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400V
NTE5643 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600V
RMS On–State Current (TC = +75°C, Conduction Angle of 360°), IT(RMS) . . . . . . . . . . . . . . . . . 2.5A
Peak Surge (Non–Repetitive) On–State Current (One Cycle, at 50Hz or 60Hz), ITSM . . . . . . . . 30A
Peak Gate–Trigger Current (3µs Max), IGTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1A
Peak Gate–Power Dissipation (IGT ≤ IGTM for 3µs Max), PGM . . . . . . . . . . . . . . . . . . . . . . . . . . . 20W
Average Gate–Power Dissipation, PG(AV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200mW
Fusing Current (For TRIAC Protection, T = 1.25 to 10ms), I2t . . . . . . . . . . . . . . . . . . . . . . . . . . . 3A2s
Operating Temperature Range, Topr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40° to +100°C
Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40° to +150°C
Typical Thermal Resistance, Junction–to–Case, RthJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4°C/W
Note 1. All values apply in either direction.
Electrical Characteristics: (At Maximum Ratings and TC = +25°C unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Peak Off–State Current
IDROM VDROM = Max Rating, TJ = +100°C, –
Gate Open, Note 1
– 0.75 mA
Maximum On–State Voltage
VTM iT = 5A (Peak), Note 1
–
DC Holding Current
IH Gate Open
–
Critical Rate–of–Rise of Off–State Voltage Critical vD = VDROM, TC = +100°C, Note 1 –
dv/dt
– 2.2 V
– 15 mA
7
– V/µs
DC Gate–Trigger Current
DC Gate–Trigger Voltage
Gate–Controlled Turn–On Time
IGT vD = 6V, RL = 39Ω, All Quads
–
VGT vD = 6V, RL = 39Ω
–
tgt vD = VDROM, IGT = 80mA, tr = 0.1µs, –
iT = 10A (Peak)
– 25 mA
– 2.2 V
2.2 – µs