DS481 Datasheet, PDF (6/10 Pages) National Semiconductor (TI) – Low Power RS-485/RS-422 Multipoint Transceiver with Sleep Mode | |||
|
◁ |
Parameter Measurement Information (Continued)
DS012919-15
*Note: Non Terminated, Open Input only
FIGURE 14. Entering Sleep Mode Conditions (modes and exit parameters shown)
TABLE 1. Device Pin Descriptions
Pin
Name
Description
No.
1
RO
Receiver Output: When RE (Receiver Enable) is LOW, the receiver is enabled (ON), if DO/RI ⥠DO
(Note 1)/RI (Note 1) by 200 mV, RO will be HIGH. If DO/RI ⤠DO (Note 1)/RI (Note 1) by 200 mV,
RO will be LOW. Additionally RO will be HIGH for OPEN (Non-terminated) Inputs.
2
RE
Receiver Output Enable: When RE (Note 1) is LOW the receiver output is enabled. When RE (Note
(Note 1) 1) is HIGH, the receiver output is in TRI-STATE (OFF). When RE (Note 1) is HIGH and DE is LOW,
the device will enter a low-current sleep mode after 600 ns.
3
DE
Driver Output Enable: When DE is HIGH, the driver outputs are enabled. When DE is LOW, the
driver outputs are in TRI-STATE (OFF). When RE (Note 1) is HIGH and DE is LOW, the device will
enter a low-current sleep mode after 600 ns.
4
DI
Driver Input: When DE (Driver Enable) is HIGH, the driver is enabled, if DI is LOW, then DO/RI will
be LOW and DO (Note 1)/RI (Note 1) will be HIGH. If DI is HIGH, then DO/RI is HIGH and DO
(Note 1)/RI (Note 1) is LOW.
5
GND Ground Connection.
6
DO/RI Driver Output/Receiver Input, 485 Bus Pin.
7
DO
Driver Output/Receiver Input, 485 Bus Pin.
(Note 1)
/RI
(Note 1)
8
VCC
Positive Power Supply Connection: Recommended operating range for VCC is +4.75V to +5.25V.
Unit Load
A unit load for an RS-485 receiver is defined by the input cur-
rent versus the input voltage curve. The gray shaded region
is the defined operating range from â7V to +12V. The top
border extending from â3V at 0 mA to +12V at +1 mA is de-
fined as one unit load. Likewise, the bottom border extending
from +5V at 0 mA to â7V at â0.8 mA is also defined as one
unit load (see Figure 15 ). An RS-485 driver is capable of
driving up to 32 unit loads. This allows up to 32 nodes on a
single bus. Although sufficient for many applications, it is
sometimes desirable to have even more nodes.
The DS481 has 1â2 unit load and 1â4 unit load (UL) options
available. These devices will allow up to 64 nodes or 128
nodes guaranteed over temperature depending upon which
option is selected. The 1â2 UL option is available in industrial
temperature and the 1â4 UL is available in commercial tem-
perature.
First, for a 1â2 UL device the top and bottom borders shown in
Figure 15 are scaled. Both 0 mA reference points at +5V and
â3V stay the same. The other reference points are +12V at
+0.5 mA for the top border and â7V at â0.4 mA for the bot-
tom border (see Figure 15 ). Second, for a 1â4 UL device the
top and bottom borders shown in Figure 15 are scaled also.
Again, both 0 mA reference points at +5V and â3V stay the
same. The other reference points are +12V at +0.25 mA for
the top border and â7V at â0.2 mA for the bottom border
(see Figure 15 ).
The advantage of the 1â2 UL and 1â4 UL devices is the in-
creased number of nodes on one bus. In a single master