Symbol
Parameter
Conditions
VOUTMAX
IOUT
IOUT-CC
ROUT
CLOAD
IS
Maximum Output Voltage Swing
Output Current
Short Circuit Current
Output Impedance
Capacitive Load Drive Overshoot
Total Quiescent Current
RL = 600Ω
RL = 2kΩ
RL = 10kΩ
RL = 600Ω, VS = ±17V
fIN = 10kHz
Closed-Loop
Open-Loop
100pF
IOUT = 0mA
LME49740
Typical
Limit
(Note 6) (Notes 7, 8)
±13.6
±12.5
±14.0
±14.1
±26
±23
+30
–38
Units
(Limits)
V (min)
V (min)
V (min)
mA (min)
mA
mA
0.01
Ω
13
Ω
16
%
18.5
20
mA (max)
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur.
Note 2: Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications
and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance characteristics
may degrade when the device is not operated under the listed test conditions.
Note 3: Amplifier output connected to GND, any number of amplifiers within a package.
Note 4: Human body model, 100pF discharged through a 1.5kΩ resistor.
Note 5: Machine Model ESD test is covered by specification EIAJ IC-121-1981. A 200pF cap is charged to the specified voltage and then discharged directly into
the IC with no external series resistor (resistance of discharge path must be under 50Ω).
Note 6: Typical specifications are specified at +25ºC and represent the most likely parametric norm.
Note 7: Tested limits are guaranteed to National's AOQL (Average Outgoing Quality Level).
Note 8: Datasheet min/max specification limits are guaranteed by design, test, or statistical analysis.
Note 9: PSRR is measured as follows: VOS is measured at two supply voltages, ±5V and ±15V. PSRR = |20log(ΔVOS/ΔVS)|.
www.national.com