English
Language : 

LM341 Datasheet, PDF (3/11 Pages) National Semiconductor (TI) – 3-Terminal Positive Voltage Regulators
Electrical Characteristics
Limits in standard typeface are for TJ = 25˚C, and limits in boldface type apply over the −40˚C to +125˚C operating temperature
range. Limits are guaranteed by production testing or correlation techniques using standard Statistical Quality Control (SQC)
methods. (Continued)
LM341-12, LM78M12C
Unless otherwise specified: VIN = 19V, CIN = 0.33 µF, CO = 0.1 µF
Symbol
Parameter
Conditions
VO
Output Voltage
IL= 500 mA
5 mA ≤ IL ≤ 500 mA
VR LINE
Line Regulation
PD ≤ 7.5W, 14.8V ≤ VIN ≤ 27V
14.5V ≤ VIN ≤ 30V
IL = 100 mA
IL = 500 mA
VR LOAD
IQ
Load Regulation
Quiescent Current
5 mA ≤ IL ≤ 500 mA
IL = 500 mA
∆IQ
Quiescent Current Change
5 mA ≤ IL ≤ 500 mA
14.8V ≤ VIN ≤ 30V, IL = 500 mA
Vn
Output Noise Voltage
f = 10 Hz to 100 kHz
Ripple Rejection
f = 120 Hz, IL = 500 mA
Min Typ Max
11.5 12 12.5
11.4 12 12.6
120
240
240
4
10.0
0.5
1.0
75
71
Units
V
mV
mA
µV
dB
VIN
Input Voltage Required
IL = 500 mA
to Maintain Line Regulation
∆VO
Long Term Stability
IL = 500 mA
14.5
V
48 mV/khrs
LM341-15, LM78M15C
Unless otherwise specified: VIN = 23V, CIN = 0.33 µF, CO = 0.1 µF
Symbol
Parameter
Conditions
VO
Output Voltage
IL= 500 mA
5 mA ≤ IL ≤ 500 mA
VR LINE
Line Regulation
PD ≤ 7.5W, 18V ≤ VIN ≤ 30V
17.6V ≤ VIN ≤ 30V
IL = 100 mA
IL = 500 mA
VR LOAD
IQ
Load Regulation
Quiescent Current
5 mA ≤ IL ≤ 500 mA
IL = 500 mA
∆IQ
Quiescent Current Change
5 mA ≤ IL ≤ 500 mA
18V ≤ VIN ≤ 30V, IL = 500 mA
Vn
Output Noise Voltage
f = 10 Hz to 100 kHz
Ripple Rejection
f = 120 Hz, IL = 500 mA
Min Typ Max
14.4 15 15.6
14.25 15 15.75
150
300
300
4
10.0
0.5
1.0
90
69
Units
V
mV
mA
µV
dB
VIN
Input Voltage Required
IL = 500 mA
to Maintain Line Regulation
17.6
V
∆VO
Long Term Stability
IL = 500 mA
60
mV/khrs
Note 1: Absolute maximum ratings indicate limits beyond which damage to the component may occur. Electrical specifications do not apply when operating the de-
vice outside of its rated operating conditions.
Note 2: The typical thermal resistance of the three package types is:
T (TO-220) package: θ(JA) = 60 ˚C/W, θ(JC) = 5 ˚C/W
H (TO-39) package: θ(JA) = 120 ˚C/W, θ(JC) = 18 ˚C/W
DT (TO-252) package: θ(JA) = 92 ˚C/W, θ(JC) = 10 ˚C/W
3
www.national.com