English
Language : 

DS96177 Datasheet, PDF (3/8 Pages) National Semiconductor (TI) – RS-485/RS-422 Differential Bus Repeater
Electrical Characteristics (Notes 3, 4) (Continued)
Over recommended temperature, common mode input voltage, and supply voltage ranges, unless otherwise specified
Symbol
Parameter
Conditions
Min Typ Max
RECEIVER SECTION
VIC
Enable Input Clamp Voltage
VOH
High Level Output Voltage
VOL
Low Level Output Voltage
IOZ
High-Impedance State Output
II
Line Input Current (Note 9)
IIH
Enable Input Current HIGH
IIL
Enable Input Current LOW
RI
Input Resistance
IOS
Short Circuit Output Current
ICC
Supply Current (Total Package)
II = −18 mA
−1.5
VID = 200 mV, IOH = −400 µA, Figure 3 2.7
VID = −200 mV,
IOL = 8.0 mA
0.45
Figure 3
IOL = 16 mA
0.50
VO = 0.4V
−360
VO = 2.4V
20
Other Input = 0V
VI = 12V
1.0
VI = −7.0V
−0.8
VIH = 2.7V
20
VIL = 0.4V
−100
12
(Note 10)
−15
−85
No Load
Outputs Enabled
35
Outputs Disabled
40
Units
V
V
V
µA
mA
µA
µA
kΩ
mA
mA
Drive Switching Characteristics
VCC = 5.0V, TA = 25˚C
Symbol
Parameter
Conditions
tDD
Differential Output Delay Time
tTD
Differential Output Transition Time
tPLH
Propagation Delay Time,
RL = 60Ω, Figure 4
RL = 60Ω, Figure 4
RL = 27Ω, Figure 5
Low-to-High Level Output
tPHL
Propagation Delay Time,
RL = 27Ω, Figure 5
High-to-Low Level Output
tPZH
Output Enable Time to High Level
RL = 110Ω, Figure 6
tPZL
Output Enable Time to Low Level
RL = 110Ω, Figure 7
tPHZ
Output Disable Time from High Level
RL = 110Ω, Figure 6
tPLZ
Output Disable Time from Low Level
RL = 110Ω, Figure 7
Min Typ Max Units
15 25
ns
15 25
ns
12 20
ns
12 20
ns
25 45
ns
25 40
ns
20 25
ns
29 35
ns
Receiver Switching Characteristics
VCC = 5.0V, TA = 25˚C
Symbol
Parameter
Conditions
Min
Typ
Max
Units
tPLH
Propagation Delay Time,
Low-to-High Level Output
tPHL
Propagation Delay Time,
High-to-Low Level Output
VID = 0V to 3.0V,
CL = 15 pF, Figure 8
16
25
ns
16
25
ns
tPZH
Output Enable Time to High Level
CL = 15 pF, Figure 9
tPZL
Output Enable Time to Low Level
tPHZ
Output Disable Time from High Level
CL = 5.0 pF, Figure 9
tPLZ
Output Disable Time from Low Level
15
22
ns
15
22
ns
14
30
ns
24
40
ns
Note 2: “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the devices
should be operated at these limits. The tables of “Electrical Characteristics” provide conditions for actual device operation.
Note 3: Unless otherwise specified Min/Max limits apply across the 0˚C to +70˚C range for the DS96177. All typicals are given for VCC = 5V and TA = 25˚C.
Note 4: All currents into the device pins are positive; all currents out of the device pins are negative. All voltages are referenced to ground unless otherwise specified.
Note 5: ∆|VOD| and ∆|VOC| are the changes in magnitude of VOD, VOC respectively, that occur when the input is changed from a high level to a low level.
Note 6: In EIA Standards RS-422A and RS-485, VOC, which is the average of the two output voltages with respect to ground, is called output offset voltage, VOS.
Note 7: The algebraic convention, when the less positive (more negative) limit is designated minimum, is used in this data sheet for common mode input voltage
and threshold voltage levels only.
3
www.national.com