English
Language : 

DS75176B Datasheet, PDF (3/8 Pages) National Semiconductor (TI) – Multipoint RS-485/RS-422 Transceivers
Electrical Characteristics (Notes 2, 3) (Continued)
0˚C ≤ TA≤ 70˚C, 4.75V < VCC< 5.25V unless otherwise specified
Symbol
Parameter
Conditions
IOSD
IOSR
Driver Short-Circuit
Output Current
Receiver Short-Circuit
Output Current
VO = −7V (Note 7)
VO = +12V (Note 7)
VO = 0V
Min Typ Max Units
−250 mA
+250 mA
−15
−85 mA
Note 1: “Absolute Maximum Ratings” are those beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the device should
be operated at these limits. The tables of “Electrical Characteristics” provide conditions for actual device operation.
Note 2: All currents into device pins are positive; all currents out of device pins are negative. All voltages are referenced to device ground unless otherwise specified.
Note 3: All typicals are given for VCC = 5V and TA = 25˚C.
Note 4: Derate linearly at 5.56 mW/˚C to 650 mW at 70˚C.
Note 5: Derate linearly @ 6.11 mW/˚C to 400 mW at 70˚C.
Note 6: Differential - Input/Output bus voltage is measured at the noninverting terminal A with respect to the inverting terminal B.
Note 7: All worst case parameters for which note 7 is applied, must be increased by 10% for DS75176BT. The other parameters remain valid for −40˚C < TA
< +85˚C.
Switching Characteristics
VCC = 5.0V, TA = 25˚C
Symbol
Parameter
tPLH
Driver Input to Output
tPHL
Driver Input to Output
tr
Driver Rise Time
tf
Driver Fall Time
tZH
Driver Enable to Output High
tZL
Driver Enable to Output Low
tLZ
Driver Disable Time from Low
tHZ
Driver Disable Time from High
tPLH
Receiver Input to Output
tPHL
Receiver Input to Output
tZL
Receiver Enable to Output Low
tZH
Receiver Enable to Output High
tLZ
Receiver Disable from Low
tHZ
Receiver Disable from High
Conditions
RLDIFF = 60Ω
CL1 = CL2 = 100 pF
RLDIFF = 60Ω
CL1 =CL2 = 100 pF
(Figure 3 and Figure 5)
CL = 100 pF (Figure 4 and Figure 6) S1
Open
CL = 100 pF (Figure 4 and Figure 6) S2
Open
CL = 15 pF (Figure 4 and Figure 6) S2
Open
CL = 15 pF (Figure 4 and Figure 6) S1
Open
CL = 15 pF (Figure 2 and Figure 7)
S1 and S2 Closed
CL = 15 pF (Figure 2 and Figure 8) S2
Open
CL = 15 pF (Figure 2 and Figure 8) S1
Open
CL = 15 pF (Figure 2 and Figure 8) S2
Open
CL = 15 pF (Figure 2 and Figure 8) S1
Open
Min Typ Max Units
12
22
ns
17
22
ns
18
ns
18
ns
29 100
ns
31
60
ns
13
30
ns
19 200
ns
30
37
ns
32
37
ns
15
20
ns
11
20
ns
28
32
ns
13
35
ns
3
www.national.com