English
Language : 

CD4029BM Datasheet, PDF (3/8 Pages) National Semiconductor (TI) – Presettable Binary/Decade Up/Down Counter
DC Electrical Characteristics CD4029BC (Note 2) (Continued)
Symbol
VIL
VIH
IOL
IOH
IIN
Parameter
Low Level
Input Voltage
High Level
Input Voltage
Low Level Output
Current (Note 3)
High Level Output
Current (Note 3)
Input Current
Conditions
VDD e 5V VO e 0 5V or 4 5V
VDD e 10V VO e 1V or 9V
VDD e 15V VO e 1 5V or 13 5V
VDD e 5V VO e 0 5V or 4 5V
VDD e 10V VO e 1V or 9V
VDD e 15V VO e 1 5V or 13 5V
VDD e 5V VO e 0 4V
VDD e 10V VO e 0 5V
VDD e 15V VO e 1 5V
VDD e 5V VO e 4 6V
VDD e 10V VO e 9 5V
VDD e 15V VO e 13 5V
VDD e 15V VIN e 0V
VDD e 15V VIN e 15V
b40 C
Min Max
15
30
40
35
70
11 0
0 52
13
36
b0 52
b1 3
b3 6
b0 3
03
Min
35
70
11 0
0 44
11
30
b0 44
b1 1
b3 0
a25 C
Typ
0 88
2 25
88
b0 88
b2 25
b8 8
b10b5
10b5
Max
15
30
40
b0 3
03
a85 C
Min Max
15
30
40
35
70
11 0
0 36
09
24
b0 36
b0 9
b2 4
b1 0
10
Units
V
V
V
V
V
V
mA
mA
mA
mA
mA
mA
mA
mA
AC Electrical Characteristics
TA e 25 C CL e 50 pF RL e 200k Input trCL e tfCL e 20 ns unless otherwise specified
Symbol
Parameter
Conditions
Min
Typ
Max
Units
CLOCKED OPERATION
tPHL or tPLH
Propagation Delay Time
to Q Outputs
VDD e 5V
VDD e 10V
VDD e 15V
200
400
ns
85
170
ns
70
140
ns
tPHL or tPLH
Propagation Delay Time
to Carry Output
VDD e 5V
VDD e 10V
VDD e 15V
320
640
ns
135
270
ns
110
220
ns
tPHL or tPLH
Propagation Delay Time
to Carry Output
CL e 15 pF
VDD e 5V
VDD e 10V
VDD e 15V
285
570
ns
120
240
ns
95
190
ns
tTHL or tTLH
Transition Time Q
or Carry Output
VDD e 5V
VDD e 10V
VDD e 15V
100
200
ns
50
100
ns
40
80
ns
tWH or tWL
Minimum Clock
Pulse Width
VDD e 5V
VDD e 10V
VDD e 15V
160
320
ns
70
135
ns
55
110
ns
trCL or tfCL
Maximum Clock Rise
VDD e 5V
15
ms
and Fall Time
VDD e 10V
10
ms
VDD e 15V
5
ms
tSU
Minimum Set-Up Time
VDD e 5V
VDD e 10V
VDD e 15V
180
360
ns
70
140
ns
55
110
ns
fCL
Maximum Clock Frequency
VDD e 5V
VDD e 10V
VDD e 15V
15
31
37
74
45
9
MHz
MHz
MHz
CIN
Average Input Capacitance
Any Input
5
75
pF
CPD
Power Dissipation Capacitance
Per Package (Note 4)
65
pF
Note 1 ‘‘Absolute Maximum Ratings’’ are those values beyond which the safety of the device cannot be guaranteed Except for ‘‘Operating Temperature Range’’
they are not meant to imply that the devices should be operated at these limits The table of ‘‘Electrical Characteristics’’ provides conditions for actual device
operation
Note 2 VSS e 0V unless otherwise specified
Note 3 IOH and IOL are tested one output at a time
3