DS96173 Datasheet, PDF (2/6 Pages) National Semiconductor (TI) – RS-485/RS-422 Quad Differential Line Receivers | |||
|
◁ |
Absolute Maximum Ratings (Note 2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Storage Temperature Range
Molded DIP
â65ËC to +150ËC
Lead Temperature
Molded DIP (soldering, 10
sec.)
265ËC
Maximum Power Dissipation (Note 1) at 25ËC
N-Molded Package
1.84W
Supply Voltage
7V
Input Voltage, A or B Inputs
±25V
Differential Input Voltage
±25V
Enable Input Voltage
7V
Low Level Output Current
50 mA
Recommended Operating
Conditions
Min Typ Max
Supply Voltage (VCC)
Common Mode Input
4.75 5 5.25
â7
+12
Voltage (VCM)
Differential Input
â7
+12
Voltage (VID)
Output Current High (IOH)
â400
Output Current LOW (IOL)
16
Operating Temperature (TA)
0
25 70
Note 1: Derate molded DIP package 15 mW/ËC above 25ËC.
Units
V
V
V
µA
mA
ËC
Electrical Characteristics (Notes 3, 4)
over recommended temperature, common mode input voltage, and supply voltage ranges, unless otherwise specified
Symbol
Parameter
Conditions
Min Typ Max Units
VTH
Differential Input
High Threshold Voltage
VO = 2.7V, IO = â 0.4 mA
0.2
V
VTL
Differential Input (Note 5)
VO = 0.5V, IO = 16 mA
â0.2
V
Low Threshold Voltage
VT+ â VTâ
Hysteresis (Note 6)
VCM = 0V
50
mV
VIH
Enable Input Voltage HIGH
2.0
V
VIL
Enable Input Voltage LOW
0.8
V
VIC
Enable Input Clamp Voltage
II = â18 mA
â1.5
V
VOH
Output Voltage HIGH
VID = 200 mV, IOH = â400 µA
2.7
V
VOL
Output Voltage LOW
VID = â200 mV
IOL = 8 mA
0.45
V
IOL = 16 mA
0.50
IOZ
High Impedance State Output
VO = 0.4V to 2.4V
±20
µA
II
Line Input Current (Note 7)
Other Input = 0V
VI = 12V
1.0
mA
VI = â7V
â0.8
IIH
Enable Input Current HIGH
VIH = 2.7V
20
µA
IIL
Enable Input Current LOW
VIL = 0.4V
â100
µA
RI
Input Resistance
12
kâ¦
IOS
Short Circuit Output Current
(Note 8)
â15
â85
mA
ICC
Supply Current
Outputs Disabled
75
mA
Note 2: âAbsolute Maximum Ratingsâ are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the devices
should be operated at these limits. The tables of âElectrical Characteristicsâ provide conditions for actual device operation.
Note 3: Unless otherwise specified Min/Max limits apply across the 0ËC to +70ËC range for the DS96173/DS96175. All typicals are given for VCC = 5V and TA = 25ËC.
Note 4: All currents into the device pins are positive; all currents out of the device pins are negative. All voltages are reference to ground unless otherwise specified.
Note 5: The algebraic convention, when the less positive (more negative) limit is designated minimum, is used in this data sheet for common mode input voltage
and threshold voltage levels only.
Note 6: Hysteresis is the difference between the positive-going input threshold voltage, VT+, and the negative going input threshold voltage, VTâ.
Note 7: Refer to EIA Standards RS-485 for exact conditions.
Note 8: Only one output at a time should be shorted.
www.national.com
2
|
▷ |