Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage (VCC)
Input Voltage (DIN)
Enable Input Voltage (EN,
â0.3V to +4V
â0.3V to (VCC + 0.3V)
EN*)
Output Voltage (DOUT+, DOUTâ)
Short Circuit Duration
â0.3V to (VCC + 0.3V)
â0.3V to +3.9V
(DOUT+, DOUTâ)
Continuous
Maximum Package Power Dissipation @ +25ËC
M Package
1088 mW
MTC Package
866 mW
Derate M Package
8.5 mW/ËC above +25ËC
Derate MTC Package
6.9 mW/ËC above +25ËC
Storage Temperature Range
Lead Temperature Range
Soldering (4 sec.)
Maximum Junction
Temperature
ESD Rating (Note 10)
(HBM, 1.5 kâ¦, 100 pF)
(EIAJ, 0 â¦, 200 pF)
â65ËC to +150ËC
+260ËC
+150ËC
⥠10 kV
⥠1200 V
Recommended Operating
Conditions
Supply Voltage (VCC)
Operating Free Air
Temperature (TA)
Min Typ Max Units
+3.0 +3.3 +3.6 V
â40 +25 +85 ËC
Electrical Characteristics
Over supply voltage and operating temperature ranges, unless otherwise specified. (Notes 2, 3, 4)
Symbol
Parameter
Conditions
Pin
Min
VOD1
âVOD1
Differential Output Voltage
Change in Magnitude of VOD1 for
Complementary Output States
RL = 100⦠(Figure 1)
DOUTâ
DOUT+
250
VOS
âVOS
Offset Voltage
Change in Magnitude of VOS for
Complementary Output States
1.125
VOH
VOL
VIH
VIL
IIH
IIL
VCL
IOS
IOSD
Output High Voltage
Output Low Voltage
Input High Voltage
Input Low Voltage
Input High Current
Input Low Current
Input Clamp Voltage
Output Short Circuit Current
(Note 11)
Differential Output Short Circuit
Current (Note 11)
VIN = VCC or 2.5V
VIN = GND or 0.4V
ICL = â18 mA
ENABLED,
DIN = VCC, DOUT+ = 0V or
DIN = GND, DOUTâ = 0V
ENABLED, VOD = 0V
DIN,
EN,
EN*
DOUTâ
DOUT+
0.90
2.0
GND
â10
â10
â1.5
IOFF
Power-off Leakage
VOUT = 0V or 3.6V, VCC = 0V
â20
or Open
IOZ
Output TRI-STATE Current
EN = 0.8V and EN* = 2.0V
VOUT = 0V or VCC
ICC
No Load Supply current Drivers DIN = VCC or GND
Enabled
â10
VCC
ICCL
ICCZ
Loaded Supply Current Drivers
Enabled
No Load Supply Current Drivers
Disabled
RL = 100⦠All Channels, DIN =
VCC or GND (all inputs)
DIN = VCC or GND, EN = GND,
EN* = VCC
Typ
310
1
1.17
1
1.33
1.02
2
â2
â0.8
â4.2
â4.2
±1
±1
4.0
20
2.2
Max
450
35
1.375
25
1.6
VCC
0.8
+10
+10
â9.0
â9.0
+20
+10
8.0
30
6.0
Units
mV
|mV|
V
|mV|
V
V
V
V
µA
µA
V
mA
mA
µA
µA
mA
mA
mA
www.national.com
2
|
▷ |