English
Language : 

DS75154 Datasheet, PDF (2/8 Pages) National Semiconductor (TI) – Quad Line Receiver
Absolute Maximum Ratings (Note 2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Normal Supply Voltage (Pin 15),
(VCC1)
Alternate Supply Voltage (Pin 16),
(VCC2)
Input Voltage
7V
14V
±25V
Storage Temperature Range
−65˚C to +150˚C
Maximum Power Dissipation (Note 1) at 25˚C
SO Package
650 mW
Lead Temperature (Soldering, 4
seconds)
260˚C
Operating Conditions
Min Max Units
Supply Voltage (Pin 15), (VCC1)
Alternate Supply Voltage
4.5 5.5
V
(Pin 16), (VCC2)
Input Voltage
10.8 13.2
V
±15
V
Temperature, (TA)
0
+70
˚C
Note 1: Derate molded DIP package 10.9 mW/˚C above 25˚C; derate SO
package 8.01 mW/˚C above 25˚C.
Electrical Characteristics (Notes 3, 4, 5)
Symbol
VIH
VIL
VT+
Parameter
High-Level Input Voltage
Low-Level Input Voltage
Positive-Going Threshold Voltage
VT−
Negative-Going Threshold Voltage
VT+−VT−
Hysteresis
VOH
High-Level Output Voltage
VOL
Low-Level Output Voltage
rI
Input Resistance
VI(OPEN)
IOS
ICC1
ICC2
Open-Circuit Input Voltage
Short-Circuit Output Current
(Note 6)
Supply Current From VCC1
Supply Current From VCC2
Conditions
(Figure 1)
(Figure 1)
(Figure 1)
Normal Operation
Fail-Safe Operation
(Figure 1)
Normal Operation
Fail-Safe Operation
(Figure 1)
Normal Operation
Fail-Safe Operation
IOH=−400 µA, (Figure 1)
IOL=16 mA, (Figure 1)
(Figure 2)
∆VI=−25V to −14V
∆VI=−14V to −3V
∆VI=−3V to +3V
∆VI=3V to 14V
∆VI=14V to 25V
II=0, (Figure 3)
VCC1=5.5V, VI=−5V, (Figure 4)
VCC1=5.5V, TA=25˚C, (Figure 5)
VCC2=13.2V, TA=25˚C, (Figure 5)
Min Typ Max Units
3
V
−3
V
0.8
2.2
3
V
0.8
2.2
3
V
−3 −1.1
0
V
0.8
1.4
3
V
0.8
3.3
6
V
0
0.8
2.2
V
2.4
3.5
V
0.23 0.4
V
3
5
7
kΩ
3
5
7
kΩ
3
6
kΩ
3
5
7
kΩ
3
5
7
kΩ
0
0.2
2
V
−10 −20 −40
mA
20
35
mA
23
40
mA
Switching Characteristics
(VCC1=5V, TA=25˚C)
Symbol
Parameter
tPLH
Propagation Delay Time, Low-to-High
Level Output
tPHL
Propagation Delay Time, High-to-Low
Level Output
tTLH
Transition Time, Low-to-High Level
Output
tTHL
Transition Time, High-to-Low Level
Output
Conditions
CL=50 pF, RL=390Ω, (Figure 6)
CL=50 pF, RL=390Ω, (Figure 6)
CL=50 pF, RL=390Ω, (Figure 6)
CL=50 pF, RL=390Ω, (Figure 6)
Min Typ Max Units
22
ns
20
ns
9
ns
6
ns
Note 2: “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. Except for “Operating Temperature Range” they
are not meant to imply that the devices should be operated at these limits. The table of “Electrical Characteristics” provides conditions for actual device operation.
Note 3: Unless otherwise specified min/max limits apply across the 0˚C to +70˚C range for the DS75154. All typical values are for TA=25˚C and VCC1=5V.
Note 4: All currents into device pins shown as positive, out of device pins as negative, all voltages referenced to ground unless otherwise noted. All values shown
as max or min on absolute value basis.
www.national.com
2