Absolute Maximum Ratings (Note 1)
If Military Aerospace specified devices are required
please contact the National Semiconductor Sales
Office Distributors for availability and specifications
Supply Voltage (VCC
Input Voltage
7V
5 5V
OFF-State Voltage Applied to
Open-Collector Outputs
12V
Maximum Power Dissipation at 25 C
Cavity Package
1433 mW
Molded Package
1362 mW
Operating Free-Air Temperature Range
DS55114
b55 C to a125 C
DS75114
0 C to a70 C
Storage Temperature Range
b65 C to a150 C
Lead Temperature ( from case
for 60 seconds) J Package
300 C
Lead Temperature ( from case
for 4 seconds) N Package
260 C
Derate cavity package 9 6 mW C above 25 C derate molded package
10 9 mW C above 25 C (Note 2)
Operating Conditions
Min Max Units
Supply Voltage (VCC)
DS75114
4 75 5 25
V
High Level Output Current (IOH)
Low Level Output Current (IOL)
Operating Free-Air
b40 mA
40
mA
Temperature (TA)
DS75114
0
70
C
Electrical Characteristics Over recommended operating free-air temperature range (unless otherwise noted)
DS75114
Symbol
Parameter
Conditions (Note 3)
Typ
Units
Min (Note 4) Max
VIH
VIL
VIK
VOH
VOL
VOK
IO(off)
II
High Level Input Voltage
2
Low Level Input Voltage
Input Clamp Voltage
VCC e Min II e b12 mA
High Level Output Voltage VCC e Min VIH e 2V
IOH e b10 mA 2 4
VIL e 0 8V
IOH e b40 mA 2
Low Level Output Voltage
VCC e Min VIH e 2V VIL e 0 8V
IOL e 40 mA
Output Clamp Voltage
VCC e 5V IO e 40 mA TA e 25 C
VCC e Max IO e b40 mA TA e 25 C
OFF-State Open-Collector
Output Current
VCC e Max
VOH e 12V
VOH e 5 25V
TA e 25
TA e 125 C
TA e 25 C
TA e 70 C
Input Current at Maximum VCC e Max VI e 5 5V
Input Voltage
V
08
b0 9
b1 5
V
34
V
30
02
0 45
V
61
65
V
b1 1 b1 5
mA
1
100
200
1
mA
IIH
High Level Input Current
VCC e Max VI e 2 4V
IIL
Low Level Input Current
VCC e Max VI e 0 4V
IOS
Short-Circuit Output
Current (Note 5)
VCC e Max VO e 0V
b40
b1 1
b90
40
mA
b1 6 mA
b120 mA
ICC
Supply Current
(Both Drivers)
Inputs Grounded No Load
TA e 25 C
VCC e Max
VCC e 7V
37
50
mA
47
70
Note 1 All voltage values are with respect to network ground terminal
Note 2 For operation above 25 C free-air temperature refer to Dissipation Derating Curves in the Thermal information section
Note 3 All parameters with the exception of OFF-state open-collector output current are measured with the active pull-up connected to the sink output
Note 4 All typical values are at TA e 25 C and VCC e 5V with the exception of ICC at 7V
Note 5 Only one output should be shorted at a time and duration of the short-circuit should not exceed one second
http www national com