The two I/O pins associated with a timer subsystem function
as independent PWM outputs in the dual 8-bit PWM mode.
If a PWM timer is stopped using its associated
MODE.TxRUN bit the following actions result:
„ The associated TIOx pin will return to its default value as
defined by the IOxCTL.PxPOL bit.
„ The counter will stop and will retain its last value.
„ Any pending updates of the PERCAPx and DTYCAPx
register will be completed.
„ The prescaler counter will be stopped and reset if both
MODE.TxRUN bits are cleared.
Figure 52 illustrates the configuration of a timer subsystem
while operating in dual 8-bit PWM mode. The numbering in
Figure 52 refers to timer subsystem 1 but equally applies to
the other three timer subsystems.
Figure 53 illustrates the configuration of a timer subsystem
while operating in 16-bit PWM mode. The numbering in
Figure 53 refers to timer subsystem 1 but equally applies to
the other three timer subsystems.
7
0
C1PRSC
==
Prescaler
Counter
TMOD1 = 10
15
Restart
T1RUN
Count1[15:0]
0
[15:0]
7
0
C1PRSC
==
Prescaler
Counter
TMOD1 = 01
Compare
PERCAP1[15:0]
Compare
DTYCAP1[15:0]
T2RUN
T1RUN
RQ
RQ
S
S
15
Res COUNT1[15:8]
0
[15:8]
Compare
PERCAP1[15:8]
7
Res COUNT1[7:0]
Compare
PERCAP1[7:0]
0
[7:0]
Compare
DTYCAP1[15:8]
Compare
DTYCAP1[7:0]
RQ
S
RQ
S
P2POL
TIO2
P1POL
TIO1
DS090
Figure 52. VTU Dual 8-Bit PWM Mode
23.1.2 16-Bit PWM Mode
Each of the four timer subsystems may be independently
configured to provide a single 16-bit PWM channel. In this
case the lower and upper bytes of the counter are concate-
nated to form a single 16-bit counter.
Operation in 16-bit PWM mode is conceptually identical to
the dual 8-bit PWM operation as outlined under Dual 8-bit
PWM Mode on page 145. The 16-bit timer may be started
or stopped with the lower MODE.TxRUN bit, i.e. T1RUN for
timer subsystem 1.
The two TIOx outputs associated with a timer subsystem
can be used to produce either two identical PWM wave-
forms or two PWM waveforms of opposite polarities. This
can be accomplished by setting the two PxPOL bits of the
respective timer subsystem to either identical or opposite
values.
P2POL
TIO2
P1POL
TIO1
DS091
Figure 53. VTU 16-bit PWM Mode
23.1.3 Dual 16-Bit Capture Mode
In addition to the two PWM modes, each timer subsystem
may be configured to operate in an input capture mode
which provides two 16-bit capture channels. The input cap-
ture mode can be used to precisely measure the period and
duty cycle of external signals.
In capture mode the counter COUNTx operates as a 16-bit
up-counter while the two TIOx pins associated with a timer
subsystem operate as capture inputs. A capture event on
the TIOx pins causes the contents of the counter register
(COUNTx) to be copied to the PERCAPx or DTYCAPx reg-
isters respectively.
Starting the counter is identical to the 16-bit PWM mode, i.e.
setting the lower of the two MODE.TxRUN bits will start the
counter and the clock prescaler. In addition, the capture
event inputs are enabled once the MODE.TxRUN bit is set.
The TIOx capture inputs can be independently configured to
detect a capture event on either a positive transition, a neg-
ative transition or both a positive and a negative transition.
In addition, any capture event may be used to reset the
counter COUNTx and the clock prescaler counter. This
avoids the need for software to keep track of timer overflow
conditions and greatly simplifies the direct frequency and
duty cycle measurement of an external signal.
www.national.com