Application Hints (Continued)
As shown in the graph below, increasing the copper area
beyond 1 square inch produces very little improvement. The
minimum value for θJA for the TO-263 package mounted to a
PCB is 32˚C/W.
Figure 2 shows the maximum allowable power dissipation
for TO-263 packages for different ambient temperatures,
assuming θJA is 35˚C/W and the maximum junction tempera-
ture is 125˚C.
20069526
FIGURE 2. Maximum power dissipation vs ambient
temperature for TO-263 package
www.national.com