English
Language : 

JPM16B-A Datasheet, PDF (2/5 Pages) Nihon Kaiheiki Industry Co. Ltd. – Internationally Approved Pushbuttons
Series JP Internationally Approved Pushbuttons
General Specifications
Electrical Capacity (Resistive Load)
Power Level: 10A @ 125/250V AC for JPM models & 16A @ 125/250V AC for JPL models
Other Ratings
Contact Resistance:
Insulation Resistance:
Dielectric Strength:
Mechanical Life:
Electrical Life:
Nominal Operating Force:
Contact Timing:
Latchdown:
Travel:
20 milliohms maximum
1,000 megohms minimum @ 500V DC
2,000V AC minimum between contacts for 1 minute minimum;
4,000V AC minimum between contacts & case for 1 minute minimum
25,000 operations minimum
25,000 operations minimum
JPM Single Pole 3.53N & Double Pole 6.47N
JPL Single Pole 4.51N & Double Pole 9.02 N
Nonshorting (break before make)
Normal position - flush with barrier; latchdown position - .079” (2.0mm) below normal
Pretravel .059” (1.5mm); Overtravel .071” (1.8mm); Total Travel .130” (3.3mm)
Materials & Finishes
Housing/Frame & Barrier:
Interior Seal:
Case/Base:
Polyamide (UL94V-0)
Polyphenylene sulfide (UL94V-0)
Melamine (UL94V-0)
Movable Contacts:
Stationary Contacts:
Terminals:
Silver alloy
Silver alloy
Brass with silver plating
Environmental Data
Operating Temp Range:
Humidity:
Vibration:
Shock:
Process Seal:
–10°C through +70°C (+14°F through +158°F)
90 ~ 95% humidity for 96 hours @ 40°C (104°F)
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range & returning
in 1 minute; 3 right angled directions for 2 hours
50G (490m/s2) acceleration (tested in 6 right angled directions, with 5 shocks in each direction)
Dust resistant inner seal
Installation
Soldering Time & Temp: Manual Soldering: See Profile A in Supplement section.
Standards & Certifications
Flammability Standards: UL94V-0 for housing/frame, barrier, interior seal, & case/base
TV Ratings for UL & CSA: JPM (TV-5) Overload Test @ 125V AC for 50 operations:
UL File No. WOYR2.E44145
Steady State Current (rms) 7.5A; Minimum Inrush Current (peak) 111A
C-UL File No. WOYR8.E44145 JPM (TV-5) Endurance Test @ 125V AC for 25,000 operations:
Steady State Current (rms) 5A; Minimum Inrush Current (peak) 78A
JPL (TV-8) Overload Test @ 125V AC for 50 operations:
Steady State Current (rms) 12A; Minimum Inrush Current (peak) 163A
JPL (TV-8) Endurance Test @ 125V AC for 25,000 operations:
Steady State Current (rms) 8A; Minimum Inrush Current (peak) 117A
UL Recognized: All JPM models certified at 10A @ 125V AC, TV5 & JPL models at 16A @ 125V AC, TV8;
add “/U” after part number to request marking on case; C-UL File No. WOYR2.E44145.
C-UL Certified: All JPM models certified at 10A @ 125V AC, TV5 & JPL models at 16A @ 125V AC, TV8;
R
add “/C-UL” after part number to request marking on case; C-UL File No. WOYR8.E44145.
VDE Approved: All JPM models approved at steady state 5A, inrush 80A, resistive 10A, &
DVE
motor load 6A all at 250V AC; add “/V” after part number to request marking on case;
VDE License No. 113494.
All JPL models approved at steady state 8A, inrush 128A, resistive 16A, &
motor load 8A all at 250V AC; add “/V” after part number to request marking on case;
VDE License No. 097579.
NKK Switches • email: sales@nkkswitches.com • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com 03-07