English
Language : 

JF15RP1CC_10 Datasheet, PDF (1/6 Pages) Nihon Kaiheiki Industry Co. Ltd. – Illuminated Ultra-Thin Process Sealed Tactiles
Series JF
Illuminated Ultra-Thin Process Sealed Tactiles
General Specifications
Electrical Capacity (Resistive Load)
Low/Logic Level: 50mA @ 24V DC
Other Ratings
Contact Resistance:
Insulation Resistance:
Dielectric Strength:
Mechanical Life:
Electrical Life:
Nominal Operating Force:
Total Travel:
50 milliohms maximum
500 megohms minimum @ 250V DC
250V AC minimum for 1 minute minimum
500,000 operations minimum
500,000 operations minimum
3.0N for flush actuator
2.0N for sculptured actuator
Flush Actuators .016” (0.4mm); Sculptured Actuator: .031” (0.8mm)
Materials & Finishes
Actuator:
Case:
Seal:
Base:
Movable Contact:
Stationary Contacts:
Terminals:
Polyamide for spot illuminated; polycarbonate for full face
Glass fiber reinforced polyamide
Nitrile butadiene rubber
Glass fiber reinforced polyester
Phosphor bronze with silver plating
Brass with silver plating
Brass with silver plating
Environmental Data
Operating Temperature Range:
Humidity:
Vibration:
J
Shock:
–25°C through +70°C (–13°F through +158°F)
90 ~ 95% humidity for 96 hours @ 40°C (104°F)
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range & returning
in 1 minute; 3 right angled directions for 2 hours
50G (490m/s2) acceleration (tested in 6 right angled directions, with 5 shocks in each direction)
PCB Processing
Soldering:
Cleaning:
Wave Soldering recommended. See Profile A in Supplement section.
Manual Soldering: See Profile A in Supplement section.
Automated cleaning. See Cleaning specifications in Supplement section.
Switches should not be operated or have any pressure on the actuators during cleaning.
Full face illuminated models suitable only for bottom board spray wash to avoid contamination
of the 2-layered actuator, which may compromise the aesthetics.
Standards & Certifications
The JF Series tactiles have not been tested for UL recognition or CSA certification.
These switches are designed for use in a low-voltage, low-current, logic-level circuit.
When used as intended in a logic-level circuit, the results do not produce hazardous energy.
J40
w w w.nkk.com