English
Language : 

G12KP-YA_16 Datasheet, PDF (1/4 Pages) Nihon Kaiheiki Industry Co. Ltd. – General Specifications
Series G
Process Sealed Ultra-Miniature Rockers
General Specifications
B
Electrical Capacity (Resistive Load)
Logic Level: 0.4VA maximum @ 28V AC/DC maximum
(Applicable Range 0.1mA ~ 0.1A @ 20mV ~ 28V)
Note: Find additional explanation of operating range in Supplement section.
Other Ratings
Contact Resistance:
Insulation Resistance:
Dielectric Strength:
Mechanical Life:
Electrical Life:
Nominal Operating Force:
Angle of Throw:
80 milliohms maximum
500 megohms minimum @ 500V DC
500V AC minimum for 1 minute minimum
100,000 operations minimum for On-None-On & On-Off-On
50,000 operations minimum for other circuits
100,000 operations minimum for On-None-On & On-Off-On
50,000 operations minimum for other circuits
.81N for momentary & 1.06N for maintained
28°
Materials & Finishes
Actuator:
Case:
Sealing Rings:
Movable Contact:
Stationary Contacts:
Base:
Terminals:
Glass fiber reinforced polyamide
Glass fiber reinforced polyamide
Nitrile butadiene rubber
Phosphor bronze with gold plating
Phosphor bronze with gold plating
Glass fiber reinforced polyamide
Phosphor bronze with gold plating
Environmental Data
Operating Temperature Range:
Humidity:
Vibration:
Shock:
–25°C through +85°C (–13°F through +185°F)
90 ~ 95% humidity for 96 hours @ 40°C (104°F)
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range & returning
in 1 minute; 3 right angled directions for 2 hours
50G (490m/s2) acceleration (tested in 6 right angled directions, with 5 shocks in each direction)
Installation
Cap Installation Force: 39.1N (8.8 lbf) maximum downward force on actuator
PCB Processing
Soldering:
Cleaning:
Wave Soldering Recommended: See Profile A in Supplement section.
Manual Soldering: See Profile A in Supplement section.
Automated cleaning. See Cleaning specifications in Supplement section.
Standards & Certifications
The G Series rockers have not been tested for UL recognition or CSA certification.
These switches are designed for use in a low-voltage, low-current, logic-level circuit.
When used as intended in a logic-level circuit, the results do not produce hazardous energy.
B28
w w w.nkks w it ches.com