English
Language : 

B12JJPC Datasheet, PDF (1/4 Pages) Nihon Kaiheiki Industry Co. Ltd. – Subminiature Fully Illuminated Toggles
Series B
Subminiature Fully Illuminated Toggles
A
General Specifications
Electrical Capacity (Resistive Load)
Logic Level: 0.4VA maximum @ 28V AC/DC maximum
(Applicable Range 0.1mA ~ 0.1A @ 20mV ~ 28V)
Note: Find additional explanation of operating range in Supplement section.
Other Ratings
Contact Resistance:
Insulation Resistance:
Dielectric Strength:
Mechanical Life:
Electrical Life:
Nominal Operating Force:
Contact Timing:
Angle of Throw:
50 milliohms maximum
500 megohms minimum @ 500V DC
500V AC minimum for 1 minute minimum
100,000 operations minimum
50,000 operations minimum
1.18N
Nonshorting (break-before-make)
26°
Materials & Finishes
Actuator:
Bushing Housing:
Case Housing:
Support Bracket:
Movable Contact:
Stationary Contacts:
Terminals:
Polyamide
Polyamide
Glass fiber reinforced polyamide
Phosphor bronze with tin plating
Phosphor bronze with gold plating
Brass with tin plating
Brass with gold plating
Environmental Data
Operating Temperature Range:
Humidity:
Vibration:
Shock:
–25°C through +55°C (–13°F through +131°F)
90 ~ 95% humidity for 240 hours @ 40°C (104°F)
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range
& returning in 5 minutes; 3 right angled directions for 2 hours
50G (490m/s2) acceleration (tested in 3 right angled directions, with 5 shocks in each direction)
PCB Processing
Soldering:
Cleaning:
Wave Soldering recommended. See Profile A in Supplement section.
Manual Soldering: See Profile A in Supplement section.
Automated alcohol based cleaning recommended, 5 minutes maximum. Do not use high-purity
alcohol (50% alcohol or more) or organic solvent. High alcohol solution can damage clear plastic.
See Cleaning specifications in Supplement section.
Standards & Certifications
The B Series illuminated toggles have not been tested for UL recognition or CSA certification.
These switches are designed for use in a low-voltage, low-current, logic-level circuit.
When used as intended in a logic-level circuit, the results do not produce hazardous energy.
A20